DECAN_F2_Service(Eng_Ver1).pdf - 第369页
14-29 Board 14.7. 16 Axis Board 14.7.1. Required Tools Crosshead (Phillips) screwdriv er and flathead screwdriver T W rench or Hex W rench Nipper (Remove the Cable Tie) 14.7.2. 16 Axis Board Replacement Procedure 1…

14-28
Fast & Flexible Chip Shooter DECAN F2 Service Manual
6) When assembling a board, set the DIP switch as shown in the following figure.
7) Referring to the following figure, and then connect the connector.

14-29
Board
14.7. 16 Axis Board
14.7.1. Required Tools
Crosshead (Phillips) screwdriver and flathead screwdriver
T Wrench or Hex Wrench
Nipper (Remove the Cable Tie)
14.7.2. 16 Axis Board Replacement Procedure
1) Close the PC as usual and turn off the main switch at the front of the machine.
2) Turn off the main power supply to the machine.
Warning Before servicing the machine, turn off the power switch
located at the front bottom as well as the main circuit
breaker at the rear bottom of the machine. Otherwise,
serious personal injury may occur. Perform servicing with
the power supply to the machine cut off without fail.
Warning Be sure to wear anti-electrostatic gloves when servicing the
machine.

14-30
Fast & Flexible Chip Shooter DECAN F2 Service Manual
3) Remove the rear cover.
4) Unscrew the fixing bolts(6-M3*6) securing the 16 Axis Board using a wrench and
remove it.
5) Assemble in the Rear Electric Panel a new Board.
Ref The part number of the new Board is AM06-000943B.