17-46 Fast & Flexible Chip Shooter DECAN F2 Service Manual 2. Check the SBC Board assembling and operation state. 3. Check the CAN Master Board assembling and operation state. 4. Check the PCI Board assembling and op…

17-45
Troubleshooting
E0B00 Defective emergency switch connection
[Cause]
Defective emergency switch contact
[How to Check]
Check the connection status of the emergency switch cable and check the operation
status of the emergency switch contact
[Measures]
Reassemble the emergency switch.
Replace the safety control board.
E0B01 Infected by a virus
[Cause]
Infected by a virus
[How to Check]
Perform a virus check using an anti-virus program
[Measures]
Treat it with an anti-virus program, or if it is not possible to treat it, perform HDD
recovery and reinstall the MMI.
E0B02 The NCIO board is not properly inserted into the back plane board slot
[Cause]
The NCIO board is not properly inserted into the back plane board slot
[How to Check]
Check whether the NCIO board is properly inserted into the back plane board slot
[Measures]
Insert the NCIO board into the back plane board slot properly.
E0B03 Defective PCI I/O Board contact
[Cause]
Defective PCI I/O Board contact
[How to Check]
1. Check the PCI Board assembling and operation state.
Undervoltage
related alarm
Voltage is low E0B12
Cause Description Remarks

17-46
Fast & Flexible Chip Shooter DECAN F2 Service Manual
2. Check the SBC Board assembling and operation state.
3. Check the CAN Master Board assembling and operation state.
4. Check the PCI Board assembling and operation state.
5. Check the SBC Board assembling and operation state.
6. Check the CAN Master Board assembling and operation state.
7. Check the Back Plane Board assembling and operation state.
[Measures]
Reassemble the PCI I/O Board.
E0B04 Defective CAN Conveyor Board
[Cause]
Defective CAN Conveyor Board
[How to Check]
1. Check the 24V power input state of the CAN Conveyor Board (LED turned on).
Check the output voltage of the Power Supply#1 (24V).
2. Replace the CAN Conveyor Board.
[Measures]
Replace the CAN Conveyor Board.
E0B05 Defect Safety Override Key contact
[Cause]
Defective Safety Override Key contact
[How to Check]
Check the state of the Safety Override Key contact.
[Measures]
Reassemble the Safety Override Key.
E0B06 Defective Step Driver
[Cause]
Defective Step Driver
[How to Check]
1. Check the Step Driver operation state.
2. Check the X7043S Board operation state.
[Measures]
Replace the Step Driver.

17-47
Troubleshooting
E0B07 Defective Step Driver
[Cause]
Defective Step Driver
[How to Check]
1. Check the Step Driver operation state.
2. Check the X7043S Board operation state.
[Measures]
Replace the Step Driver.
E0B08 Defective CAN Master Board (In the case of DECAN F2, SLM, SM471 and SM48X
machines, the Axis I/O Board is defective.)
[Cause]
Defective CAN Master Board
(In the case of DECAN F2, SLM, SM471 and SM48X machines, the Axis I/O Board
is defective.)
[How to Check]
1. Check the PCI Board assembling and operation state.
(Check the DPRAM Cable assembling state)
2. Check the SBC Board assembling and operation state.
3. Check the CAN Master Board assembling and operation state.
4. Check the PCI Board assembling and operation state.
5. Check the SBC Board assembling and operation state.
6. Check the CAN Master Board assembling and operation state.
7. Check the Back Plane Board assembling and operation state.
[Measures]
Replace the CAN Master Board.
Remove the PCI, CAN Master DPRam Cable and SBC Board. Then clean and
reassemble them.
E0B09 Defective Magnetic Contactor
[Cause]
Defective Magnetic Contactor
[How to Check]
1. Check the MC input power supply.
2. Check the contact state when turning on/off the MC.
[Measures]