DECAN_F2_Service(Eng_Ver1).pdf - 第571页

18-51 Machine Calibration 6. Press <Update> button to apply th e calibration result to the machine Memo The reference values for the Z-offset are as follows.  Head1~ Head6: -1.5 ~ 1.5 mm If the Z offset value exce…

100%1 / 604
18-50
Fast & Flexible Chip Shooter DECAN F2 Service Manual
2. In the <Grid> group, select the Z axis for which the calibration is to be performed and
click the <Detect Z Offset> button after selecting the <Automatic> check box.
3. The head moves to the designated position on the ANC automatically. Then the
machine creates pneumatic pressure and performs calibration while moving the
spindle down from Head 1 to Head 10 in order.
4. If the calibration is completed, the calibration result is reflected on the Z column of the
<Grid> group automatically. When performing calibration manually, insert the CN040
nozzle into each head in order manually and move down the spindle to perform
calibration while checking the pneumatic pressure of the head in the Vacuum dialog
box.
5. Once the calibration is completed for Gantry 1, select ‘Gantry2’ in the <Gantry>
combo box and perform calibration in the same manner.
18-51
Machine Calibration
6. Press <Update> button to apply the calibration result to the machine
Memo The reference values for the Z-offset are as follows.
Head1~ Head6: -1.5 ~ 1.5 mm
If the Z offset value exceeds this range, it means that the head has a
serious problem. Therefore, check for the home location, spindle,
LM, and verify if the motor operates normally.
The following is the procedure to perform the ‘R-Offset Calibration’.
1. In the <Grid> area, input “0” for all R-axis values of the heads for which the
calibration is to be performed.
2. In the <Grid> group, select the R-axis for which the calibration is to be performed and
click the <Nozzle Holder Check> button.
18-52
Fast & Flexible Chip Shooter DECAN F2 Service Manual
3. Then the message “Please Check and Register Nozzle CNT0 to ANC 1-2 Hole. First,
We must Put all Nozzles from Heads manually. To Moving Down Z Axis, Click
[Next]” appears in the message window.Remove all nozzles inserted in the nozzle-
holder manually by clicking the <Next> button. At this time, for the ANC, the virtual
nozzle CNT0 is set for the No. 1 hole of the ANC and it is regarded that the
corresponding head picked the CNT0 nozzle.
4. Then the message “Up to Align Height and Mirror Close. To Move, Click [Next].”
appears. Then move the spindle to the part recognition height so that the nozzle holder
of the head can be seen from the fly camera and click the <Next> button to close the
mirror.
5. Execute the ‘Current Position’ dialog box by clicking the shortcut menu.