DECAN_F2_Service(Eng_Ver1).pdf - 第259页
12-9 Motor Driver 1 1) Once ‘T rans’ is finished, click ‘EEP’ . Then the ‘W riting to EEPROM’ window appears since the parameter inside the exis ting amplifier is different from the file parameter . Click ‘OK’. 12.4.3. H…

12-8
Fast & Flexible Chip Shooter DECAN F2 Service Manual
8) Select the driver shaft file into which parameters are to be inputted and click ‘OK’.
9) Click ‘OK’ in the following screen.
10) If the following Parameter Dialog is created, click the ‘Trans’ button.

12-9
Motor Driver
11) Once ‘Trans’ is finished, click ‘EEP’. Then the ‘Writing to EEPROM’ window
appears since the parameter inside the existing amplifier is different from the file
parameter. Click ‘OK’.
12.4.3. How to set the Y-axis parameter (including magnetic pole estimation
method)
1) Press the Emergency switch to prevent any malfunction of the machine.
2) Run the PANATERM.
3) 'Select ‘Connect AMP’.

12-10
Fast & Flexible Chip Shooter DECAN F2 Service Manual
4) In order to connect the AMP in the manufacturer mode, enter the password (3470448)
in the current screen.
5) Select the Series.
6) 'Click ‘Parameter'->'Read from AMP'->'OK' in order.