13-63 Software 편의사항 25 Opt Home Method Use 15 Const 1: Not performed newly if XY homing is performed before during actual placement 2 : Not performed newly if Z homing is performed before actual placement 4 : Not perform…

13-62
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Fiducial 11 Opt Bad First Use 0
Const 0: Fiducial mark first
1: Bad markfirst
69 Opt Man Fid Assist
Enable
Use 0
Const 0:Normal
3: Deletes the screen for the manual fiducial ENT
function and Retry function
72 Opt Fid Dist Chk
Use
1
Const 0: The function to check the distance between fiducials is
not used
1: Generates an error when the distance between
fiducials exceeds the allowable value (1mm)
Tray 12 Opt Tray Timel
Use
0
Const 0: Pallet Change to basic. Stable pallet change
1: Fast pallet change
2: Pallet change as fast as possible
16 Opt Tray Nonstop
Use
0
Const For setup of the FW12M/S tray feeder as non-stop or not.
When the non-stop function of another model is used, it
must be set to ‘0’.
0: Tray Non Stop not used
1: Used
24 Opt Tray Link
Use
0
Const Whether to use the Auto Link of the tray part
0: AUTO LINK
1: NOT LINK
Module No Name Div Value Unit Description

13-63
Software
편의사항
25
Opt Home Method
Use
15
Const 1: Not performed newly if XY homing is performed before
during actual placement
2 : Not performed newly if Z homing is performed before
actual placement
4 : Not performed newly if R homing is performed before
actual placement
8 : Not performed newly if MIR homing is performed
during actual placement
16 : Not performed newly if BUT homing is performed
before actual placement
33
Opt Lts Method
Use
0
0: Not used
1: Used
41
Opt Light Saver Time
Out
Use
300
Const Refers to the function that turns off all illuminations after
the time set here to protect the illumination
Conveyor 19 Opt Quicklload
Use
1
Const 1: Quick Work->Use of Out Sensor
16: Sync Move (Quick Load previous)
99 CV Config User Sel
Use
1
Const 0: CV Not selected
1: CV Selected
Module No Name Div Value Unit Description

13-64
Fast & Flexible Chip Shooter DECAN F2 Service Manual
Docking 63 Opt DC Safety
Use
4
Const It is possible to check the sensors related to docking cart
safety by option:
0: All safety sensors checked
1: Left/right docking detection sensor check cleared
2: Door open state check cleared
4: Docking cart cable connection state check cleared
Mir 32 Opt Use Mir Safety
Use
0
Const Currently set so that it will not change according to the
value.
0 : Not used
1 : Used only for homing
ANC 34 Opt NZ Vis Chk
Use
0
Const Check whether there is a nozzle in the ANC pocket
before placing the nozzle:
0: Not Checked
1: checked
64 Opt ANC Shutter
Use
50
Const Use the function minimizing the ANC shutter Open/Close
movement when getting a nozzle
0: Not Checked
1: checked
Module No Name Div Value Unit Description