18-11 Machine Calibration Set the resolution of the camera in X dir ection. The unit used is the number of pixels per mm. <Y> edit box Set the resolution of the camera in Y direc tion. The unit is the number of p…

18-10
Fast & Flexible Chip Shooter DECAN F2 Service Manual
18.2. Camera [F5]
Sets various data on the camera.
Figure18.6 “Camera Setting” dialog box
<Camera Select> combo box
Select the camera type to set. Available camera types are as follows.
Move Camera: Camera used for position teaching or fiducial mark check.
Fly Camera: Camera used for component check, it is attached to each
head.Above screen is the case where the camera type is set to “Fiducial Camera”.
Warning Operation error caused by unauthorized or untrained
personnel or insufficient checking before calibration could
severely damage the equipment or the set up data, or it
could cause personal injury of the operator or the worker
near the equipment. Before carrying out calibration, check
the item to be calibrated and check if there is any worker
near the equipment. And calibration must be carried out by
an authorized and trained user only.
<Scale Data> group
Sets the scale of the camera selected from the <Camera Select> combo box. It can be
set up directly and performing calibration for the camera will input the result value
automatically.
<X> edit box

18-11
Machine Calibration
Set the resolution of the camera in X direction. The unit used is the number of
pixels per mm.
<Y> edit box
Set the resolution of the camera in Y direction. The unit is the number of pixels
per mm.
<R> edit box
Setup the R-axis assembling condition of the camera. The unit is degree.
<Offset Data> group
Sets the camera offset selected from the <Camera Select> combo box. It can be set up
directly and performing calibration for the camera will input the result value
automatically.
<X> edit box
Set the offset value of the camera in X direction between the center of the each
head and center of the camera.
<Y> edit box
Setup the Y-direction offset value of each head center and the camera center.
<R> edit box
Setup the R-direction offset value of each head center and the camera center.
<Default Light> group
Set the default light value. Please refer to “7.1.1 Common Align Data”for more
information.
<Position Data> group
Set the position of the fix camera.
<X> edit box
Set the X position value of the fix camera.
<Y> edit box
Set the Y position value of the fix camera.
<Ref. Fid. Offset Data> group
Each head has its own reference fiducial mark, which is used to correct the offset.
<Teach> group
Set the position offset of the fix camera.
combo box
Used for moving the selected object to the position of fix camera by rotating XY
axis driving motor, or for obtaining the present coordinates of the fiducial camera
Fid Cam: Selects fiducial camera.

18-12
Fast & Flexible Chip Shooter DECAN F2 Service Manual
<Move> button
Move the object selected in the combo box to the position of the assigned
coordinates. At this time, before executing <Move> button, the fix camera
corresponding to the desired position must be clicked on with a mouse.
<Get> button
Obtain coordinates for XY axis with reference to the object selected in the combo
box. At this time, before executing <Get> button, the fix camera corresponding to
the desired position must be clicked on with a mouse.
<Fiducial Mark …> button
Only fix camera is activated. Used for setting up the position of the fiducial mark of
the fix camera located at the upper part of ANC.