DECAN_F2_Service(Eng_Ver1).pdf - 第498页
17-86 Fast & Flexible Chip Shooter DECAN F2 Service Manual 17.3.16. Abnormal inline and CAN communication (E14) E1400 An error occurred to the Can communication [Cause] Defective Can board po wer cable [How to Chec…

17-85
Troubleshooting
[Measures]
Insert the SBC board into the vision board again.
E1302 Damage to the file due to infection by a virus
[Cause]
Damage to the file due to infection by a virus
[How to Check]
Perform a virus check using an anti-virus program
Reinstall the MMI
Reinstall the Windows and MMI
[Measures]
Perform virus treatment.
Perform HDD recovery and reinstall the MMI.

17-86
Fast & Flexible Chip Shooter DECAN F2 Service Manual
17.3.16. Abnormal inline and CAN communication (E14)
E1400 An error occurred to the Can communication
[Cause]
Defective Can board power cable
[How to Check]
Check the +24V Power Supply output
Check the the operation state and cables of the base control board as well as GIOEX
and NCIO boards
[Measures]
Replace the power supply unit.
Replace the cable and board.
E1401 Defective MPU-STOP IO node
[Cause]
Defective board of the corresponding node or defective cable
[How to Check]
Check the board of the AF and AR nodes.
NODE 1: AF SILL
NODE 2: AF Camera Switch Board
NODE 3: AF Head Memory Board
NODE 4: AR Camera Switch Board
NODE 5: AR Head Memory Board
Check the board of the BF and BR nodes.
Cause Description Remarks
Abnormal inline and CAN
communication
An error occurred to the Can communication E1400
Defective MPU-STOP IO node E1401
Defective operation of the Can communication
board
E1402
Abnormal Can communication board operation
and communication error
E1403
Can communication error - I/O Node "0" E1404
Defective communication with the machine at
the previous stage
E1405
Defective communication with the machine at
the next stage
E1406

17-87
Troubleshooting
NODE 11: BF SILL
NODE 12: BF Camera Switch Board
NODE 13: BF Head Memory Board
NODE 14: BR Camera Switch Board
NODE 15: BR Head Memory Board
[Measures]
Replace the board of the corresponding node.
E1402 Defective operation of the Can communication board
[Cause]
Defective connection of the Can cable
[How to Check]
Check whether the I/O of the specific board works properly
Check the LED light and power supply of the corresponding board
Check the Can communication cable
Replace the corresponding board
[Measures]
Check whether the I/O works properly.
Check the LED light and power supply.
Check the connection of the Can communication cable.
Replace the board.
E1403 Abnormal Can communication board operation and communication error
[Cause]
Abnormal Can node setup
[How to Check]
Check whether the I/O of the specific board works properly
Check the LED light and power supply of the corresponding board
Check the node select switch of the corresponding board
Check the Can communication cable
Replace the corresponding board
[Measures]
Check whether the I/O works properly.
Check the LED light and power supply.
Check the Can communication cable.