Fast & Flexible Chip Shooter DECAN F2 Service Manual
3) Unscrew the fixing bolts(2-M3*6) securing the Sensor using a wrench and remove it.
4) Assemble in the Y Fame a new Sensor.
Ref The part number of the new Sensor is J3212022A.
5) When assembling the Sensor, refer to the following.
When assembling the sensor, have the sensor connector facing in the direction as
shown in the following figure and secure it with cable ties.
10-13
Y-Axis Frame
6) Perform the following calibrations.
Axis Home Calibration
Common X-Y (1'st)
Thermal Mapping
Gantry Mapping
ANC, Position Teaching
Time: 0.8 hour