00195982-03_SM_SWS_EN.pdf - 第223页

10 Option Die Attach Unit SWS 10.1 Installing the Option Die Attach Unit SWS Service Manual SIPLACE Wafer System (SWS) 11/2018 223 Installation position of Die Attach Unit in the SWS Fig.291: Fastening screws The Die At…

100%1 / 506
10 Option Die Attach Unit SWS
10.1 Installing the Option Die Attach Unit SWS
222 Service Manual SIPLACE Wafer System (SWS) 11/2018
Fig.290:
► Put the removed parts into a bag and store the bag in the flip chip reject bin. Store all parts in-
side the SWS service box to have them available when removing the Die Attach Unit again.
10 Option Die Attach Unit SWS
10.1 Installing the Option Die Attach Unit SWS
Service Manual SIPLACE Wafer System (SWS) 11/2018 223
Installation position of Die Attach Unit in the SWS
Fig.291: Fastening screws
The Die Attach Unit is fastened (M5x16) to the ground plate of the SWS with three screws as
shown!
Fig.292:
► Carefully place the Die Attach Unit into that position!
► The transfer X-axis must not hit the raceway of the Flip-Unit!
► Pull back the transfer X axis and place the Die Attach Unit on the ground plate.
CAUTION
When placing the Die Attach Unit on the ground plate, observe the following points:
► Hold back the transfer X axis.
► Place the Die Attach Unit on the ground plate of the SWS and align the Die Attach
Unit with the screw positions.
► Carefully insert the transfer X axis in the raceway of the flip head (cutout in the race-
way).
ð Otherwise, the transfer X axis can be damaged.
10 Option Die Attach Unit SWS
10.1 Installing the Option Die Attach Unit SWS
224 Service Manual SIPLACE Wafer System (SWS) 11/2018
Fig.293:
► Remove the lower safety screws (7) of the vacuum valve Y6. Loosen the upper screw (8) and
rotate the valve Y6 (11) around the position of the locking screw No.1(12) (M5x16) to get
access to the Die Attach Unit.
► Insert the Die Attach safety screw but do not tighten it yet.
Fig.294:
► Insert the safety screw No. 2 (M5x16) of the Die Attach Unit and slightly tighten it.