15 Calibration
15.2 Activation of setup operation at the SWS (hard and software)
362 Service Manual SIPLACE Wafer System (SWS) 11/2018
15.2.2 Concept of retrofit for setup operation
Fig.518:
15 Calibration
15.2 Activation of setup operation at the SWS (hard and software)
Service Manual SIPLACE Wafer System (SWS) 11/2018 363
15.2.3 Preparation of the software
To get access to the mounting plate for enabling the setup mode, the magazine lift must be in the
magazine change position.
The following steps must be performed:
Fig.519:
► Choose Settings (1).
► Choose User Settings (2).
► Choose Machine Service (3).
► Enter the password (4) for the access level Machine Service → service1
► Choose Login (5).
Fig.520:
► Choose Service (6).
► Choose Calibration of wafer changer (7).
15 Calibration
15.2 Activation of setup operation at the SWS (hard and software)
364 Service Manual SIPLACE Wafer System (SWS) 11/2018
Fig.521:
► Choose Calibration wafer lift (8).
► Choose the Positions tab (9).
► Choose Go to position (10) to move the lifting table to the magazine change position.
15.2.4 Changing the cables at the mounting plate to allow for setup mode
Tools required
●
Machine key
●
Allen key 5mm
Procedure
► Open the front door of the magazine lift by using the machine key!
Fig.522:
► Open the tower lock screw (2) by using the Allen key 5mm (the screw has a lost protection).