10 Option Die Attach Unit SWS
10.1 Installing the Option Die Attach Unit SWS
Service Manual SIPLACE Wafer System (SWS) 11/2018 239
Fig.318:
► Next, the window Calibration of die attach axes displays information on what the calibration
wizard will do in this specific step and what the operator has to do.
In Step 1 there is nothing to do for the operator.
► Choose Next.
Fig.319:
► Step 2 is performed automatically.
Perform the following steps as instructed on the screen:
10 Option Die Attach Unit SWS
10.1 Installing the Option Die Attach Unit SWS
240 Service Manual SIPLACE Wafer System (SWS) 11/2018
Fig.320:
► Remove the calibration tool from the Die Attach drive. Remove the fastening screw for this
(see figure).
Fig.321:
► Remove the nozzle from the Die Attach segment and turn the segment in the upper transfer
position. Fit the gauge (see figure).
► Choose Next.
ð After successful calibration, the window with Step 3 is displayed.
10 Option Die Attach Unit SWS
10.1 Installing the Option Die Attach Unit SWS
Service Manual SIPLACE Wafer System (SWS) 11/2018 241
Fig.322:
Fig.323:
► Mount the gauge back at its the original position.
► Choose Next.
ð The following window with Step 4 is displayed.