00195982-03_SM_SWS_EN.pdf - 第471页
17 Tips and tricks 17.1 Moving the Z axis for die ejector downwards in the switched off and removed SWS Service Manual SIPLACE Wafer System (SWS) 11/2018 471 17 Tips and tricks 17.1 Moving the Z axis for die ejector down…

16 Software
16.4 Restoring an old software version (GUI)
470 Service Manual SIPLACE Wafer System (SWS) 11/2018
Fig.735: Software configuration menu
► Press ESC.
Fig.736: Setup tool menu
► Press ESC.
Fig.737: Message: exiting the setup tool
► Confirm YES with Enter.

17 Tips and tricks
17.1 Moving the Z axis for die ejector downwards in the switched off and removed SWS
Service Manual SIPLACE Wafer System (SWS) 11/2018 471
17 Tips and tricks
17.1 Moving the Z axis for die ejector downwards in the
switched off and removed SWS
If the Z axis of the die ejector is still in the top position after the SWS has been switched off and re-
moved, you can move this axis to the down position as follows:
Fig.738:
1. Die ejector in top position
2. Base plate
3. Pneumatic connection for die ejector

17 Tips and tricks
17.1 Moving the Z axis for die ejector downwards in the switched off and removed SWS
472 Service Manual SIPLACE Wafer System (SWS) 11/2018
Procedure for lowering
Fig.739:
► Search the die ejector pneumatic unit (3) for the "lifting cylinder infeed" (4)hose.