00195982-03_SM_SWS_EN.pdf - 第300页
12 Wafer stretcher 12.6 Fitting the wafer stretcher 300 Service Manual SIPLACE Wafer System (SWS) 11/2018 Fig.427: ► Run the pneumatic hose and connect it to the coupling (1) . ► Position the coupling between the mounti…

12 Wafer stretcher
12.6 Fitting the wafer stretcher
Service Manual SIPLACE Wafer System (SWS) 11/2018 299
Fig.425:
► Push the wafer stretcher to the other side.
Make sure that the cable chain which is still rolled out and the cable itself do not get caught
anywhere.
Pay attention to the wafer changer (gripper) as well.
12.6.3 Fitting the connections
Fig.426:
► Roll up the cable chain and run it at the prescribed place.

12 Wafer stretcher
12.6 Fitting the wafer stretcher
300 Service Manual SIPLACE Wafer System (SWS) 11/2018
Fig.427:
► Run the pneumatic hose and connect it to the coupling (1).
► Position the coupling between the mounting plate and the blue sensor control.
► Fix the inlet hose with a cable tie (2) to the spacer bolt.
► Run the connection hose to the SWS, free of folds, around the two spacer bolts.
► Fix the hose with a cable tie (3).
Fig.428:
► Use the Allen countersunk screw to fit the presence sensor in the place provided (1).
Pay attention to the sensor orientation upwards (2) (see diagram).
Assembly must be conducted parallel to the edges.

12 Wafer stretcher
12.6 Fitting the wafer stretcher
Service Manual SIPLACE Wafer System (SWS) 11/2018 301
Fig.429:
► Fit the cable duct with the two pan-head screws.
Fig.430:
► Connect the ground cable.
► Connect connector X11.
Fig.431:
► Fit the cover plate with the six screws.
Run the pneumatic connection as shown in the diagram.