16 Software 16.2 Installation of operating system Service Manual SIPLACE Wafer System (SWS) 11/2018 425 Fig.632: As soon as you have entered a text at Effect , the Generate report button will be enabled. ► After describ…

100%1 / 506
16 Software
16.2 Installation of operating system
424 Service Manual SIPLACE Wafer System (SWS) 11/2018
16.2.1.6 Backup via bug report
Another option for backing up the SWS calibration and product data is to generate a bug report.
However, in this case, the necessary backup files can only be restored by specially trained soft-
ware specialists.
Creating a bug report
► Press the key combination Ctrl+Alt+B.
ð The following window will open:
Fig.631:
► Enter your name at Reporter.
► Describe the problem at Effect.
16 Software
16.2 Installation of operating system
Service Manual SIPLACE Wafer System (SWS) 11/2018 425
Fig.632:
As soon as you have entered a text at Effect, the Generate report button will be enabled.
► After describing the problem, select on the Generate report button.
ð After the bug report has been successfully completed, the notifications line at the bottom
edge of the bug report windows will show the message Bug report successfully fin-
ished!
► Click on the Copy to disc button to save the data generated by the bug report.
16 Software
16.2 Installation of operating system
426 Service Manual SIPLACE Wafer System (SWS) 11/2018
Fig.633:
The Copy bug report to disc window will open (see below).
► Select the bug report to be saved in the left section, at Select bug report.
► Insert a USB stick into the USB port behind the SWS keyboard.
► In the righthand section of the window, you can select the target drive/folder at Select destin-
ation directory.
Go to /media and select the usbdisk0 drive.
The contents of the connected USB stick can be found here.
► Select the target folder on the USB stick and then select the Copy button.
If you do not have a memory medium available, the bug report can also be saved later on, even if
the SWS has been switched off in the meantime.
After restarting the bug reporter and selecting Copy to disc, the copy window will open, showing
the bug reports still available in the left section, where they can be copied, as described above.
► To delete a bug report which has been marked in the left section, select the Remove button.