16 Software 16.2 Installation of operating system 436 Service Manual SIPLACE Wafer System (SWS) 11/2018 16.2.2 Installation of operating system NOTICE Before the installation, you should make a note of the settings for t…

100%1 / 506
16 Software
16.2 Installation of operating system
Service Manual SIPLACE Wafer System (SWS) 11/2018 435
Fig.653:
► Select Networking.
► Select Network Interfaces.
Customer network interface
► Select Customer Network Interface.
The eth0 interface will be shown. Make a note of the addresses and the interface names. The cus-
tomer interface is need, for example, for connecting to a wafer map server (Kynesis ALPS).
SWS & station network interface
► Select SWS & Station Network Interface.
●
This shows the eth1 interface, used to connect to the station.
●
This is where the address for the connection to the station is shown, for example. These ad-
dresses are fixed as a default.
Format: 192.168.255.24x
The relevant location is entered for x. At location 2, the SWS therefore has the address
192.168.255.242.
For an overview of the addresses (eth0) for all SWSs at the station, refer to Networking -> Net-
work Addresses.
16 Software
16.2 Installation of operating system
436 Service Manual SIPLACE Wafer System (SWS) 11/2018
16.2.2 Installation of operating system
NOTICE
Before the installation, you should make a note of the settings for the fixed SWS IP ad-
dresses and the relevant placement machine location (see 16.2.1.9 "Adding network ad-
dresses" [}433]).
NOTICE
You can choose between various options during the installation.
► Use the arrow keys on your keyboard to switch between the options available.
NOTICE
► To create the required effect, confirm each entry with Enter.
Fig.654: PC in the SWS supply unit
► Start the PC (1). The PC is located behind the front door in the SWS supply unit.
► You can change the boot order in BIOS, if needed, so that the computer can be started from
the CD/DVD drive.
► Insert the CD (2).
16 Software
16.2 Installation of operating system
Service Manual SIPLACE Wafer System (SWS) 11/2018 437
16.2.2.1 Completing backup of the installed version first
WARNING
► When updating an existing system installation, first complete a backup of the installed
version (see 16.2.1.2 "Backup of Halcon license" [}416]).
► Otherwise, if you do not, you will lose the production data, calibration data and li-
censes!
► Make sure that you use the current OS version (version 8/2018: V4.0.5)
► Boot the BoxPC for the SWS.
It should be booted from the DVD. If it starts from the HDD, check the boot order in the BIOS.
► Select the OS installation Unattended from the start menu, as shown in the diagram below.
Fig.655:
After successfully restoring the system, the following message will be shown:
Fig.656:
► Remove the installation DVD and enter 3. Press Enter.
If the DVD is still in the computer during reboot, you can also choose Boot from local disk
(hd0) as an alternative. The system will then be started from the hard drive.
ð Since the GUI has not yet been installed, only the operating system, the message Ma-
chine software is missing will appear (see below).