10 Option Die Attach Unit SWS 10.1 Installing the Option Die Attach Unit SWS 242 Service Manual SIPLACE Wafer System (SWS) 11/2018 Fig.324: ► Choose Finish . ð The die attach rotation axis is initialized. ð If the calib…

10 Option Die Attach Unit SWS
10.1 Installing the Option Die Attach Unit SWS
Service Manual SIPLACE Wafer System (SWS) 11/2018 241
Fig.322:
Fig.323:
► Mount the gauge back at its the original position.
► Choose Next.
ð The following window with Step 4 is displayed.

10 Option Die Attach Unit SWS
10.1 Installing the Option Die Attach Unit SWS
242 Service Manual SIPLACE Wafer System (SWS) 11/2018
Fig.324:
► Choose Finish.
ð The die attach rotation axis is initialized.
ð If the calibration was done correctly, the segment must be in the upper transfer position
after the initialization.
10.1.5.2 Calibration of the Die Attach Transfer X Axis
► Change to the operator level Service.
Fig.325:
► Choose the Service menu and then choose the button for the transfer X axis.
► Choose the Automatic calibration button.
ð The calibration of the transfer X home position is done automatically.

10 Option Die Attach Unit SWS
10.2 Dissambling Die-Attach-Unit SWS
Service Manual SIPLACE Wafer System (SWS) 11/2018 243
10.2 Dissambling Die-Attach-Unit SWS
Required tool
●
2.5mm Allen key
Procedure
► Shut down the SWS in the GUI.
► Switch the SWS off at the main switch.
Fig.326:
► Remove the cover of the Die Attach Unit.