RS-1_instruction manual.pdf - 第194页

Part 1 B asic O peration Chapter 2 Pr oduction 2- 83 24 A retry - over occurre d when the mach ine sent data to the la ser unit. 25 A recognition trou ble occurred dur ing the once recognit ion processing. 26 A sensor tr…

100%1 / 1058
Part 1 Basic Operation Chapter 2 Production
2-82
No.
Displayed error message
52
ball Insp Err(ball detect error)
53
ball Insp Err(ball matrix size Error)
54
ball Insp Err(ball count Error)
55
ball Insp Err(ball diameter Error)
56
ball Insp Err(brightness base get error)
57
ball Insp Err(brightness characteristic get err)
58
Outline Measurement Err(Component incln is too big)
59
Outline Measurement Err(Component size is too big)
60
Outline Measurement Err(Component size is toll small)
61
Outline Measurement Err(No component)
62
Terminal component Err(Cannot detect a lead (Up side)).
63
Terminal component Err(Cannot detect a lead (Bottom side)).
64
Terminal component Err(Cannot detect a lead (Left side)).
65
Terminal component Err(Cannot detect a lead (Right side)).
66
Terminal component Err(Wrong lead width (Up side))
67
Terminal component Err(Wrong lead width (Bottom side))
68
Terminal component Err(Wrong lead width (Left side))
69
Terminal component Err(Wrong lead width (Right side))
70
Terminal component Err(Component detection error)
71
Terminal component Err(Wrong direction)
72
Terminal component Err(Component size is wrong).
73
All head vision recognize Err(Component touches the window frame).
74
Other Recognized Error
4) Error (Detail LA Recog.)
No.
Displayed error message
1
The left edge window is blocked.
2
The right edge window is blocked.
3
Both edge of window is blocked.
4
An error was caused with communication with the LNC120.
5
Failed to establish communication with the LNC120.Check to see if the LNC120 is connected to
the machine correctly.
6
Laser error: The laser always detects a component. The nozzle may be too long, or there may be
a scratch on the laser glass.
7
Detected no component even when Z is moved down.
8
Laser error: Moving the axes generates an error during laser measurement.
9
An error was generated during communication with the laser sensor, but the communication has
been recovered.
10
An error was generated during communication with the laser sensor, and the system failed to
recover the communication. Reboot the machine.
11
The shadow was undetectable during measurement.
12
An invalid parameter was specified for a command.
13
Invalid data was detected.
14
Failed to complete laser recognition.
15
Other causes abended measurement.
16
The theta encoder signal is not correctly input to LNC120.check if connector.
17
An error of an abnormal number of packets was detected in data received from the laser unit.
18
An abnormal command error was detected in data received from the laser unit
19
An abnormal address error was detected in data received from the laser unit
20
An error of an abnormal number of data records was detected in data received from the laser unit.
21
A time-out error occurred when the machine tried to establish communication with the laser unit.
22
An abnormal address error was detected in data received from the laser unit
23
A time-out error occurred when the machine sent data to the laser unit.
Part 1 Basic Operation Chapter 2 Production
2-83
24
A retry-over occurred when the machine sent data to the laser unit.
25
A recognition trouble occurred during the once recognition processing.
26
A sensor trouble was detected during the once recognition processing.
27
Although measurement had not been performed, a request for obtaining the measurement result
was issued.
28
Any measurement data was not able to be obtained.
29
A request for obtaining the measurement result was issued during rotation for measurement.
30
A request for obtaining the measurement result was issued during measurement processing.
31
Failed to obtain correct data for measurement.
32
Since the rotation center of a target to be measured is too far from the measurement center, the
machine cannot measure it.
33
Measurement is being aborted.
34
Failed to obtain data enough to measure.
35
|A request for obtaining the measurement result was issued during rotation for measurement.
(The off angle is being held.)
36
Although the laser was not initialized yet, you tried to execute the sensor function.
37
An unexpected error has occurred in the laser unit.
38
Since the set window size is too small, any measurement processing cannot be performed.
5) Error (Detail Component)
No.
Displayed error message
1
Tombstone
2
Component fall
3
Verify error
4
Component direction error
5
Pick position check error
6
Unplaced
7
Dimension
8
Pick miss
9
Ball inspection
10
Laser recog. angle error
11
Illegal component junk
12
Placement error
13
Nozzle Alignment Error
14
Interference with Laser Unit
15
Copla status error
16
Copla Colinearity error
17
Copla Coplanarity error
18
Copla lead count error
19
Copla compo pos. error
20
Copla limit error
6) Error (Detail Feeder)
No.
Displayed error message
1
No component
7) Error (Detail Setting)
No.
Displayed error message
1
Unplaced option
Part 1 Basic Operation Chapter 2 Production
2-84
8) Error (Detail MTS)
No.
Displayed error message
1
Command error
2
Parameter error
3
READY time out
4
ETX time out
5
Sync char time out
6
Response time out
7
Data error
8
Rspns error
9
Request at offline
10
Stacker Lock
11
Could not detect tray
12
Cover open
13
Supply
14
No Stacker
15
Door open
16
Component remain
17
Receive pick finish during shuttle transporting
18
MS parameter not entered
19
Request Changing Stacker when Normal Mode
20
Home position error(Z)
21
Home position error(Y)
22
Shutter close error
23
Shutter open error
24
Emergency stop
25
Over run error(Z + limit)
26
Over run error(Y + limit)
27
Y Holder Error
28
Not finish initialize
29
Mounter emergency stop
30
Over run eror(Z - limit)
31
Over run eror(Y - limit)
32
Interlock error
33
Z error
34
Y error
35
Opening Y Holder when Z Axis Moving
36
Door,Cover SW
37
Overrun error
38
Z axis sensor error
39
Y axis sensor error
40
Clamping Stacker Error
41
RAM error
42
Illegal break current
43
Holder Sensor error
44
Sensor error(Z + limit)
45
Sensor error(Y + limit)
46
Changing Stacker Error
47
NV-RAM error
48
Close/open sensor error
49
Drive Time Out(Z)
50
Driver Alarm(Y)
51
Escape Error(Y)