RS-1_instruction manual.pdf - 第198页

Part 1 B asic O peration Chapter 2 Pr oduction 2- 87 No. Displayed er ror me ssage 45 No.2 Head error 46 Over Run Shutt le 47 Y Holder Error 48 Not finish initia lize 49 Mounter emergenc y stop 50 Over ru n error(Z - lim…

100%1 / 1058
Part 1 Basic Operation Chapter 2 Production
2-86
9) Error (Detail MTC)
No.
Displayed error message
1 Command error
2 Parameter error
3 No component
4 READY time out
5 ETX time out
6 Sync char time out
7 Response time out
8 Data error
9 Rspns error
10 Request at offline
11 Stacker Lock
12 Picking error(head)
13 Picking error(shuttle)
14 Not recovery component
15 Could not detect tray
16 Cover open
17 Transport error(head)
18 Transport error(shuttle)
19 Supply
20 No Stacker
21 Door open
22 Component remain
23 BGA Holder Error
24 Detecting Board on the Conveyor
25 Receive pick finish during shuttle transporting
26 Head Vacuum No.1 Sensor
27 Shuttle Vacuum No.1 Sensor
28 Failed to detect Origin Auto PWB Conveyor
29 Teaching spot turned off
30 MS parameter not entered
31 Head Vacuum No.2 Sensor
32 Shuttle Vacuum No.2 Sensor
33 Detecting Motor Error Auto PWB conveyor
34 Home position error(Z)
35 Home position error(X)
36 Home position error(Y)
37 No.1 Head Error
38 Shuttle error
39 Shutter close error
40 Shutter open error
41 Emergency stop
42 Over run error(Z + limit)
43 Over run error(X + limit)
44 Over run error(Y + limit)
Part 1 Basic Operation Chapter 2 Production
2-87
No.
Displayed error message
45 No.2 Head error
46 Over Run Shuttle
47 Y Holder Error
48 Not finish initialize
49 Mounter emergency stop
50 Over run error(Z - limit)
51 Over run error(X - limit)
52 Over run error(Y - limit)
53 No.1 Head Sensor error
54 Over run error( Shuttle )
55 Interlock error
56 Z error
57 X error
58 Y error
59 No.2 Head Sensor error
60 Shuttle error
61 Door,Cover SW error
62 Overrun error
63 Z axis sensor error
64 X axis sensor error
65 Y axis sensor error
66 RAM error
67 Illegal break current
68 Holder Sensor error
69 Motor Off
70 Sensor error(Z + limit)
71 Sensor error(X + limit)
72 Sensor error(Y + limit)
73 Shuttle sensor error
74 NV-RAM error
75 Close/open sensor error
76 Impossible servo driver on (Z)
77 Soft Limit (Shuttle)
78 Servo alarm
79 Bulb bad motion
80 Request cancell
81 Switch Off-line
82 Switch Supply
83 Press MTC EMG Sw
84 Retry Out
85 Empty Parts
86 Supply
87 MTC COMM ERR (Data Error)
88 MTC COMM ERR (Communication Error)
89 MTC COMM ERR (Procedure Error)
90 MTC COMM ERR (Synchronous Error)
Part 1 Basic Operation Chapter 2 Production
2-88
No.
Displayed error message
91 MTC COMM ERR (Power Off)
92 Step Number of Tray is Wrong
93 MTC is not Available in Setup Data
94 Not Finding STX ETX
95 Undefined Command Code is Specified
96 Parts Request Send Multiplexy (WAIT)
97 Parts Request Send Multiplexy (KICK)
98 Parts Request is Abnormal
99 Response Time Out
100 MTC Initialize Incompletely
101 Unmovable by Off-line
102 Unmovable by Air-Down
103 IPC Object Close Error (MTC1)
104 IPC Object Close Error (MTC2)
105 IPC Object Close Error (MTS1)
106 IPC Object Close Error (MTS2)
107 IPC Object Close Error (DTS1)
108 IPC Object Close Error (DTS2)
109 IPC Object Close Error (MTC1)
110 Move error
111 Retry over
112 No component
113 Offline
114 Supply
115 Pick miss
116 Time Out (Ready Waiting Observation 10sec)
117 Time Out (Sync Character Observation 4sec)
118 Time Out (ETX Observation 3sec)
119 MTC Power Off
120 Time Out (Responseless Observation 60sec)
121 Receive Data Validity Error
122 Ring Buffer Access Error
123 Time Out (Data Link Release 1)
124 Time Out (Data Link Release 2)
125 MTC Communication Initialize Failed