Part 2 D etaile d Descript ion of E ach Functi on Chapter 8 Machine Set up 8- 60 8.4.3 Moving the axis to the de sired coordinates (1) Moving the X, Y and/or Z -axis If you select t he <Exec> b utton when you selec…

100%1 / 1058
Part 2 Detailed Description of Each Function Chapter 8 Machine Setup
8-59
(3) θ Axis Control
When [Control unit] is specified as the head, you can move the theta axis.
(4) ZA Axis Control
When [Control unit] is specified as the head, you can move the ZA-axis.
You can select only a category height where the ZA-axis can move.
- When you select any of <1mm> to <25mm> buttons, the down message appears if the
ZA-axis moves to a position lower than the current height.
Part 2 Detailed Description of Each Function Chapter 8 Machine Setup
8-60
8.4.3 Moving the axis to the desired coordinates
(1) Moving the X, Y and/or Z-axis
If you select the <Exec> button when you select the <XY Axis Control> or <Z Axis Control>
button in the Axis Kindgroup, the system moves the specified axis(axes) to the coordinates
specified in the Move Pos.field of the Free Pos.group.
(2) Speed
If you select the <Exec> button when you select <XY Axis Control>, <Z Axis Control>, or <T
Axis Control>, the selected axis is moved at the speed of Low speed 2” to High speed 2” for
XYZ axis, or at the speed of Low speedto Height speedfor theta axis.
(3) θ (theta rotation)
If you select the <Exec> button when you select the <T Axis Control> button in the “Axis
Kindgroup, the system rotates the specified unit in the theta direction by the angle you
specify here.
Part 2 Detailed Description of Each Function Chapter 8 Machine Setup
8-61
8.4.4 Air control
When [Control unit] is specified as the head, vacuum control can be exerted.
When you press <ON> or <OFF> button of Blowor Vacuum,blow control or vacuum control
can be exerted for the head selected by control unit.
Blow control and vacuum control cannot be turned on simultaneously by the same head.