RS-1_instruction manual.pdf - 第662页

Pa r t 2 D et ai l ed Des c r i pt i o n of Ea c h F unc t i o n Chapte r 6 G e neral - Purpose Vision Co mpone nt 6- 31 3. Operation on the "Ele m ent" sc ree n ① Ty p e The l ead elem ent types ar e m ai nly …

100%1 / 1058
Part 2 Detailed Description of Each Function Chapter 6 General-Purpose Vision Component
6-30
Dimension (Point, 1D or 2D)
For a lead element, the dimension is one. Select 1D.
In the example, the number of leads located in the first element group is 30. Enter 30to
the Countfield displayed under the setting item Row.
The pitch of each element group is shown in the figure.
- When the pitch is 0.5 mm, enter 0.5in the Pitchfield.
- Set “0” to the Tolerancefield.
Layout inspection
Set the level used for checking the layout of an element group (checking a bent lead of a
lead component). If you are to check the layout, check the Layout inspection check box.
In the same manner as setting of a QFP, use the ratio of a bent lead to the lead pitch to set
the bent lead detection level.
- When you want to set the level to 20 %, check the Layout inspectioncheck box, then
check 20 %.
Missing Elements
In the example, there is no missing lead on the element group. If there is/are a missing
element(s), specify this setting item also in the same manner as that of a QFP.
Up to four blocks of missing leads can be specified per element group.
To specify a block, set the position of the first missing lead and the number of missing leads
located continuously in the same manner when you set those of a QFP component.
- If three leads are not located from the fifth lead,
Enter “5” to the Startfield of the Rowsetting item, “3” to the Count field.
Here, you have finished setting an element group. Next, define a recognition element of
this element group
Only one element can be defined per element group. Even though you define two or more
elements, they are handled as invalid.
Click the <Add> button in the Elementsetting field.
Top View
Lead pitch of the first element
group
Lead pitch of the
second element group
Lead pitch of the third element
group
Lead pitch of the fourth
element group
Part 2 Detailed Description of Each Function Chapter 6 General-Purpose Vision Component
6-31
3. Operation on the "Element" screen
Type
The lead element types are mainly classified into two: inner leads and outer leads.
An inner lead refers to a lead whose end faces toward the inside of a component. An outer
lead refers to a lead whose end faces toward the outside of a component.
- In the example, a component consists of outer leads.
Select Outer Leadfrom the Typecombo box.
Reference pos. (position)
The element origin of a lead element is the lead end as described earlier.
- Select Center of the bottom from the Reference pos. combo box.
Polarity (element polarity)
Specify how bright the image of an element should be.
- Select Brightfrom the Polaritycombo box because a lead element looks bright under
the reflective light.
Offset
Normally, the offset is not used. Set “0” to the Offsetfields.
Element size
Enter the element size. In the example, the lead length is 1.0 mm, and the lead width is 0.2
mm. In this case, enter the following values:
Size Width: 0.2
Length: 1.0
Normally, the tolerance is not used. Enter “0” to the Tolerancefields.
Outer Lead/Inner Lead
Profile (lead shape)
As shown in the figure, a lead whose shape is flat entirely is called a flat lead, a
stepped lead is called a gullwing lead, and a J-shaped lead is called “J-Bend lead.
A flat lead is often used for a unidirectional connector.
A gullwing lead is often used for a QFP and SOP.
A J-Bend lead is used for a PLCC (QFJ) and SOJ.
- In the example, a gullwing lead is shown.
Select Gullwingfrom the Profilecombo box.
Example of
inner leads
(of a socket)
Gullwing lead
Flat lead
J-Bend lead
Part 2 Detailed Description of Each Function Chapter 6 General-Purpose Vision Component
6-32
Cut shape
Specify the shape of a lead end.
All of the settings other than Flatare handled in the same manner. When you select a
setting other than Flat, set the Cut widthand Cut length” fields.
- In the example, the shape of a lead end is flat.
Select Flat from the Cut shapecombo box.
Coating
This item is not to be used. Select Barefrom this combo box.
Cut width
This item is not to be used. Enter 0” to this field.
Cut length
Set this item if you select a setting other than Flatfrom the Cut shapecombo box.
Enter the length of a not-flat portion measured from the lead end.
- In the example, the shape of a lead end is flat.
Enter “0” to the Cut length field.
Lead size
For a gullwing lead, enter the lead foot size here.
The lead foot sizeindicates the portion of a gullwing lead which is in contact with a board.
- In the example, the length of a gullwing lead foot is 0.5 mm.
Enter the following values:
Width : 0.2 (same as the lead width)
Length : 0.4
Here, you have finished entering element data. When you click the <OK> button
displayed on the lower right corner, the Element Groupscreen reappears.
You have finished defining the first element group. When you click the <OK> button
displayed on the lower right corner, the Element Datascreen reappears.