RS-1_instruction manual.pdf - 第701页

Part 2 D etaile d Descript ion of E ach Functi on Chapter 7 Operation Option 7- 26 No. Menu item Description Status Operation an d detailed expl anation 4 Pick positio n offset che ck Specify t he pick po sition of fset …

100%1 / 1058
Part 2 Detailed Description of Each Function Chapter 7 Operation Option
7-25
7.5 Tracking/Inspection
Specify operation options for tracking/inspection.
7.5.1 Inspection enabled
When you press <Inspection enabled> button, the inspection enabled option setting screen
appears.
No. Menu item
Description
Status Operation and detailed explanation
1
Tombstone
Specify the execution of tombstone detection.
Tombstone detection is performed for components for which
“Tombstone” of component data is effective.
Tombstone detection is performed regardless of the component data
setting.
2
Component dimension
check
Specify the execution of the component orientation check function.
A component dimension check is made for components for which
Component dimension checkof component data is enabled.
A component dimension check is made regardless of the component
data setting.
3
Component orientation
check
Specify the execution of the component orientation check function.
The ratio between the short side and long side of component data and
the ratio resulting from measurement are compared. If the difference
is out of the certain range, this results in a component orientation error.
Part 2 Detailed Description of Each Function Chapter 7 Operation Option
7-26
No. Menu item
Description
Status Operation and detailed explanation
4
Pick position offset check
Specify the pick position offset check function.
After a component pickup, the offset value from the center of the nozzle
is judged by laser recognition. Thus, a pick position shift is detected.
5
Check nozzle alignment
in pick
Specify the execution of the nozzle alignment check function. Precision priority
is set in the machine setup, this item can be specified.
The nozzle alignment check function becomes effective. For
high-density placement, a pick position shift error occurs if the nozzle
protrudes from the component at a component pick.
6
Component mis-release
check function
Specify the execution of the component take-back check function.
The component mis-release check function becomes effective.
7
Properties checked
Specify an item to be checked.
You can select this check box only when the coplanarity unit is enabled with the
MS Parameter utility and the ratio of the colinearity is not 0.
Only Colinearity checked
The machine runs a colinearity check only.
Colinearity and
Coplanarity check
The machine runs both a colinearity check and a
coplanarity check.
Part 2 Detailed Description of Each Function Chapter 7 Operation Option
7-27
7.5.2 Inspection operation
When you press the <Inspection operation> button, the inspection operation setting screen
appears.
No. Menu item
Description
Status Operation and detailed explanation
1
Check release of
component after placing
completion
Specify the execution of a nozzle separation check of a component when the
component is placed.
Make sure by laser that no component is left in the nozzle when the
Z-axis goes up after component placement.
The [Component release check] setting of component data is ignored
and no check is made.
2
Check dimension for
laser height 0 compo.
Change the pick check height for components with a laser height of 0 or more to
prevent a detection error by nozzle.
For components for which the laser height is set to 0 or more, a pick
check by laser is made at 0.1 mm or less from the end of the nozzle.
A pick check is made by laser at the laser height regardless of the set
value of laser height.
3
Measure component
height when restarting
after component run-out
Specify the component height measurement at a start after occurrence of no
components. Unless the HMS unit is set, this item cannot be selected.
Component height measurement is executed at a start after
occurrence of no components.