RS-1_instruction manual.pdf - 第805页

Part 2 D etaile d Descript ion of E ach Functi on Chapter 9 M anual Control 9- 33 9.6.3 Other control When you se lect [Other ] – [Other control ] in the m enu, t he other contr ol dialog appe ars. (1) Calibration bl ock…

100%1 / 1058
Part 2 Detailed Description of Each Function Chapter 9 Manual Control
9-32
9.6.2 Signal light control
When you select [Other] [Signal light control] in the menu, the “Signal light controldialog
appears.
(1) Status
The status of each unit is displayed at completion of control.
(2) Control item
Select a control item by radio button. Mini signal lightcannot be selected unless it is
checked off in the option settings of the MS parameters.
This has no effect on the setting in Device enable in Machine setup.
1) Red/Yellow/Green
The light ON/Light Off/BLINK of each color of the signal light is controlled.
Select <Light On> button, <Light Off> button, <Light On/Off> button, or <BLINK> button
for control.
2) Buzzer
The ON/OFF operation of the buzzer is controlled.
Press the <ON> button, <OFF> button, or <ON/OFF> button for control.
3) Mini signal light (front/rear)
The light ON/light OFF operation of each mini signal light is controlled.
Select <Light On> button, <Light Off> button, or <Light On/Off> button for control.
Part 2 Detailed Description of Each Function Chapter 9 Manual Control
9-33
9.6.3 Other control
When you select [Other] [Other control] in the menu, the other control dialog appears.
(1) Calibration block
Select a control item by radio button and press the <ON> button, <OFF> button, or
<ON/OFF> button on the Calibration blockside for control.
1) LED control
The LED ON/OFF operation is controlled.
2) Vacuum control
The vacuum ON/OFF operation is controlled.
(2) Vacuum pump
Press the <ON> button, <OFF> button, or <ON/OFF> button on the Vacuum pump
Ejectorside for control.
Part 2 Detailed Description of Each Function Chapter 9 Manual Control
9-34
9.6.4 Other sensors
When you select [Other] [Other sensor] in the menu, the other sensor dialog appears.
The status of each sensor is displayed.
This has no effect on the setting in Device enablein Machine setup.
(The status of a sensor that is not checked off (not used) is also displayed.)
In the sensor status display, the status is read and displayed continuously.