RS-1_instruction manual.pdf - 第430页

Part 1 B asic O peration Chapter 4 Cr eating a Produc tion Progra m 4- 95 The “V ision 2” tab allows you t o set informat ion on leads locate d on each of the top and bot tom sides. Menu item Overvie w Length Enter the l…

100%1 / 1058
Part 1 Basic Operation Chapter 4 Creating a Production Program
4-94
The “Vision 2” tab allows you to set information on leads located on each side.
Menu item
Overview
Length
Enter the length of a section of a lead that is in contact with a board.
Width
Enter the width of a lead.
Count
Enter the number of leads when a component type is a lead component.
Start 1 to 3
Enter the position of a missing lead.
The input range is from 0 to the number of leads (default: 0).
Miss 1 to 3
Enter the number of missing leads.
The input range is from 0 to the number of leads (default: 0).
5) SOP, HSOP, SOJ, TSOP2
The “Vision 1” tab allows you to set the lead pitch and the lead bending level.
Menu item
Overview
Lead Pitch
Enter the distance between two consecutive leads.
Bend level
Select the bending level of a lead to be detected among “15 %,” “20 %,”
“25 %,” “30 %” and “None.
The default value is 20 %.
Part 1 Basic Operation Chapter 4 Creating a Production Program
4-95
The “Vision 2” tab allows you to set information on leads located on each of the top and bottom
sides.
Menu item
Overview
Length
Enter the length of a section of a lead that is in contact with a board.
Width
Enter the width of a lead.
Count
Enter the number of leads when a component type is a lead component.
Start 1 to 3
Enter the position of a missing lead.
The input range is from 0 to the number of leads (default: 0).
Miss 1 to 3
Enter the number of missing leads.
The input range is from 0 to the number of leads (default: 0).
6) TSOP
The “Vision 1” tab allows you to set the lead pitch and the lead bending level.
Menu item
Overview
Lead Pitch
Enter the distance between two consecutive leads.
Bend level
Select the bending level of a lead to be detected among “15 %,” “20 %,”
“25 %,” “30 %” and “None.
The default value is 20 %.
Part 1 Basic Operation Chapter 4 Creating a Production Program
4-96
The “Vision 2” tab allows you to set information on leads located on each of the left and right sides.
Menu item
Overview
Length
Enter the length of a section of a lead that is in contact with a board.
Width
Enter the width of a lead.
Count
Enter the number of leads when a component type is a lead component.
Start 1 to 3
Enter the position of a missing lead.
The input range is from 0 to the number of leads (default: 0).
Miss 1 to 3
Enter the number of missing leads.
The input range is from 0 to the number of leads (default: 0).