RS-1_instruction manual.pdf - 第616页
Part 1 B asic O peration Chapter 4 Cr eating a Produc tion Progra m 4- 281 6) Result of teachin g of a bad mark A thresho ld value is obtained and each setting va l ue for recogniz ing a bad mar k is display ed on the sc…

Part 1 Basic Operation Chapter 4 Creating a Production Program
4-280
4) Recognizing a bad mark with the OCC (while the system is obtaining the threshold value)
When you press the <OK> button on the screen for obtaining the threshold value for
recognizing a bad mark with the OCC, the system is obtaining a threshold value.
5) Recognizing a bad mark with the OCC (to set a threshold value)
When you perform a teaching operation for the menu item “Set OCC Bad Mark Threshold”
field on the “Bad Mark teaching” screen, the following dialog box appears on the screen.
When you press the <OK> button on this dialog box, the system finishes teaching.

Part 1 Basic Operation Chapter 4 Creating a Production Program
4-281
6) Result of teaching of a bad mark
A threshold value is obtained and each setting value for recognizing a bad mark is displayed
on the screen with teaching operation that recognizes a bad mark with the OCC.
For the menu item “Set OCC Bad Mark Threshold” field on the “Bad Mark teaching” screen,
the system recognizes a “Position on Bad Mark” and a “Position off Bad Mark” by teaching
operation to obtain a threshold value. Then, values obtained during this recognition
operation are entered in the following fields: “Vertical Light Parameter,” “Inclined Light
Parameter,” “Contrast Pattern,” “Window Frame (Width, Length)” and “Mark Polarity.”

Part 1 Basic Operation Chapter 4 Creating a Production Program
4-282
7) Recognizing a bad mark with the OCC (if the system fails to obtain a threshold value)
If the system fails to obtain a threshold value during teaching to recognize a bad mark with
the OCC, the message “Failed to acquire threshold Select auto-acquisition?” appears on
the screen.
① When you press the <OK> button, the system tries to obtain a threshold value
again.
② When you press the <CANCEL> button, the system finishes obtaining a threshold
value.
8) If the system fails to recognize a bad mark with the OCC (to obtain a threshold value
automatically)
If the system fails to recognize a bad mark to obtain a threshold value automatically
during teaching, the following message appears on the screen.
4.5.7.8 Single verification (option)
This command attaches the specified component on the head and compares information on the
resistor, the capacitor and the polarity set in a program (Component data) with the actual one to
check them. See Section 2.12.3 “Verify check (optional)” for details.
4.5.7.9 Continuous verification (option)
This command attaches the component that satisfies the specified conditions on the head and
compares information on the resistor, the capacitor and the polarity set in a program (Component
data) with the actual one to check them. See Section 2.12.3 “Verify check (optional)” for details.