RS-1_instruction manual.pdf - 第263页

Part 1 B asic O peration Chapter 2 Pr oduction 2- 152 Tracking If you press t he “ Trace ” button display ed in the Operation ar ea when the “Sto p” screen is displayed, the syste m enters Track i ng mode of a compon ent…

100%1 / 1058
Part 1 Basic Operation Chapter 2 Production
2-151
(3) Restart mode
Specify how to restart the suspended PWB production.
Menu item
Description
Retry
Retries to pick up and place a component that caused an error.
A feeder that is located on the station that displayed the “Stop” screen and whose components have
run out is automatically refilled with components.
Skip
Skips placement of a component that caused an error.
(4) Execution mode
Select whether to produce PWBs continuously or stop production at each step.
Menu item Description
Continuous The system continues producing PWBs until it finishes the production or the production is aborted.
Step
The system pauses at each movement operation.
Your pressing the <START> switch restarts the suspended production.
(5) Action
These buttons allow you to move the axis.
Menu item Description
Head Wait
Moves the head to the waiting position.
Laser wave
Displays the laser waveform screen and allows you to check the laser
See Section 2.15.8 Component protection.
Image data Save file
Outputs the VRAM image as a file.
Machine data Save file
Outputs machine information, error history and image information as a file.
Cover Lock Release
Unlocks the protection cover when any component is not picked up with a head.
(6) Edit Data
These buttons allow you to change data on the Retry list.
Menu item Description
Error Detail
Displays the “Error Detail” screen for the pause condition.
Supply
Refills a feeder on which components run out with components.
Get image data
Obtains information on a VCS, and then displays the detailed information on a VCS error.
See Section 2.11.4.2 Displayed screen (2) Retry list (not placed) 3) Error (Detail Mark
Recog./VCS Recog.).
Part 1 Basic Operation Chapter 2 Production
2-152
Tracking
If you press the Tracebutton displayed in the Operation area when the “Stop” screen is displayed,
the system enters Tracking mode of a component pick-up position.
You can track a component pick-up position of all feeders that supply components that caused a
retry error or a component run-out error.
However, the system does not track a component pick-up position of a feeder that is set to
“Unused.”
See Section 2.14.7 “Tracking a component pick-up position with a camera” for details.
Error Detail
When you press the <Error Detail> button on the “Pause” screen, the “Pause (Detail)” screen
appears.
(1) List of the error heads
A list of heads at which an error occurred is displayed.
Menu item Description
Head
Displays the number of each head.
Error
The displayed data is the same as that displayed in the “Error” column of the “Retry list.”
See “2) Error (Type) of Section 2.11.4.2 “Displayed screen” for details.
See “Error (Detail)” of Section 2.11.4.2 “Displayed screen” for details.
When you press the <OK> button, the system quits the “Pause (Detail)” screen, and then
displays the “Pause” screen again.
Part 1 Basic Operation Chapter 2 Production
2-153
When components run out
Overview of a component run-out error
If a retry over error occurs when the system picks up a component from a feeder, the system judges
that components have run out.
If you check the option “Stop system when components run out” on the “Operation option” screen,
the system stops PWB production temporarily when components run out, and then displays the
“Pause” screen.
When you do not check this option, the system searches an alternate feeder to continue the current
PWB production. If the system cannot continue the current PWB production, the “Retry list”
appears on the screen.
“Stop system when components run out.” of the Operation option
If this check box is checked, the system aborts the current PWB production and displays
the “Stop” screen when components run out.
Otherwise, the system searches the alternate feeder and continues the current production.
If the system cannot continue the production, it displays the Retry list.
(See Section 2.11.4 “Retry list” for details.)
Continuation of the process
The system places a component(s) on another (other) position(s) at which the system can
place it (them).
When the check box “Stop system when components run out.” of the Operation option is
not checked, the system uses the alternate feeder from the next pick-up/placement cycle if
there is.
Replenishment of components and setting of the number of components
If you replenish a component supply device with components when components run out,
set the number of components when necessary.
(See Section 2.11.1 “When the stocked components run out” for details.)
Signal light
The signal light flashes in yellow.
(The signal light flashes if the JUKI standard settings are made.
See Section 8.3.6.1 “Signal lights” of Chapter 8 “Machine Setup.”
- When you press the <START> switch, the system restarts production operation. See the
section on “Restart mode” described later also.
- When you press the <STOP> switch, the system displays the “Question” message for
temporarily stopping or aborting another station to abort PWB production.