Part 1 B asic O peration Chapter 2 Pr oduction 2- 84 8) Error (D etail – MTS ) No. Displayed er ror me ssage 1 Command er ror 2 Parameter err or 3 READY time out 4 ETX time out 5 Sync char t ime out 6 Response time out 7…

100%1 / 1058
Part 1 Basic Operation Chapter 2 Production
2-83
24
A retry-over occurred when the machine sent data to the laser unit.
25
A recognition trouble occurred during the once recognition processing.
26
A sensor trouble was detected during the once recognition processing.
27
Although measurement had not been performed, a request for obtaining the measurement result
was issued.
28
Any measurement data was not able to be obtained.
29
A request for obtaining the measurement result was issued during rotation for measurement.
30
A request for obtaining the measurement result was issued during measurement processing.
31
Failed to obtain correct data for measurement.
32
Since the rotation center of a target to be measured is too far from the measurement center, the
machine cannot measure it.
33
Measurement is being aborted.
34
Failed to obtain data enough to measure.
35
|A request for obtaining the measurement result was issued during rotation for measurement.
(The off angle is being held.)
36
Although the laser was not initialized yet, you tried to execute the sensor function.
37
An unexpected error has occurred in the laser unit.
38
Since the set window size is too small, any measurement processing cannot be performed.
5) Error (Detail Component)
No.
Displayed error message
1
Tombstone
2
Component fall
3
Verify error
4
Component direction error
5
Pick position check error
6
Unplaced
7
Dimension
8
Pick miss
9
Ball inspection
10
Laser recog. angle error
11
Illegal component junk
12
Placement error
13
Nozzle Alignment Error
14
Interference with Laser Unit
15
Copla status error
16
Copla Colinearity error
17
Copla Coplanarity error
18
Copla lead count error
19
Copla compo pos. error
20
Copla limit error
6) Error (Detail Feeder)
No.
Displayed error message
1
No component
7) Error (Detail Setting)
No.
Displayed error message
1
Unplaced option
Part 1 Basic Operation Chapter 2 Production
2-84
8) Error (Detail MTS)
No.
Displayed error message
1
Command error
2
Parameter error
3
READY time out
4
ETX time out
5
Sync char time out
6
Response time out
7
Data error
8
Rspns error
9
Request at offline
10
Stacker Lock
11
Could not detect tray
12
Cover open
13
Supply
14
No Stacker
15
Door open
16
Component remain
17
Receive pick finish during shuttle transporting
18
MS parameter not entered
19
Request Changing Stacker when Normal Mode
20
Home position error(Z)
21
Home position error(Y)
22
Shutter close error
23
Shutter open error
24
Emergency stop
25
Over run error(Z + limit)
26
Over run error(Y + limit)
27
Y Holder Error
28
Not finish initialize
29
Mounter emergency stop
30
Over run eror(Z - limit)
31
Over run eror(Y - limit)
32
Interlock error
33
Z error
34
Y error
35
Opening Y Holder when Z Axis Moving
36
Door,Cover SW
37
Overrun error
38
Z axis sensor error
39
Y axis sensor error
40
Clamping Stacker Error
41
RAM error
42
Illegal break current
43
Holder Sensor error
44
Sensor error(Z + limit)
45
Sensor error(Y + limit)
46
Changing Stacker Error
47
NV-RAM error
48
Close/open sensor error
49
Drive Time Out(Z)
50
Driver Alarm(Y)
51
Escape Error(Y)
Part 1 Basic Operation Chapter 2 Production
2-85
No.
Displayed error message
52
Tray Error.
53
Detect Compo Floating
54
Clamping Stacker Error
55
Impossible servo driver on(Z)
56
Servo alarm
57
Test Mode Moving Time Out
58
Request cancel
59
Switch Off-line
60
Switch Supply
61
Press MTC EMG Sw
62
Retry Out
63
Empty Parts
64
Supply
65
MTC COMM ERR (Data Error)
66
MTC COMM ERR (Communication Error)
67
MTC COMM ERR (Procedure Error)
68
MTC COMM ERR (Synchronous Error)
69
MTC COMM ERR (Power Off)
70
Step Number of Tray is Wrong
71
MTC is not Available in Setup Data
72
Not Finding STX ETX
73
Undefined Command Code is Specified
74
Parts Request Send Multiplexy (WAIT)
75
Parts Request Send Multiplexy (KICK)
76
Parts Request is Abnormal
77
Response Time Out
78
MTC Initialize Incompletely
79
Unmovable by Off-line
80
Unmovable by Air-Down
81
IPC Object Open Error (MTS-1)
82
IPC Object Open Error (MTS-2)
83
IPC Object Close Error (MTS-1)
84
IPC Object Close Error (MTS-2)
85
IPC Send Error (MTS-1)
86
IPC Receive Error (MTS-1)
87
IPC Send Error (MTS-2)
88
IPC Receive Error (MTS-2)
89
Move error
90
Retry over
91
No component
92
Offline
93
Supply
94
Time Out (Ready Waiting Observation 10sec)
95
Time Out (Sync Character Observation 4sec)
96
Time Out (ETX Observation 3sec)
97
MTC Power Off
98
Time Out (Responseless Observation 60sec)
99
Receive Data Validity Error
100
Ring Buffer Access Error
101
Time Out (Data Link Release 1)
102
Time Out (Data Link Release 2)
103
MTC Communication Initialize Failed