RS-1_instruction manual.pdf - 第678页
Part 2 D etaile d Descript ion of E ach Functi on Chapter 7 Operation Option 7-3 No . Operation option grou p Option item s 13 T racking/Inspec tion (Inspect ing operation ) Check compo nent release aft er the p lacement…

Part 2 Detailed Description of Each Function Chapter 7 Operation Option
7-2
No. Operation option group Option items
7 Production (Action)
Simultaneous Nozzle Change
Check nozzle orientation.
Acquire nozzle height when attaching nozzle.
Auto-Correct pick position.
Do not place the component when a vacuum part existence check fails.
When components are picked up sequentially, they start moving before pick-up
check finishes completely.
Measure Height of PWB
Measure height of PWB immediately before placement
All Feed
VCS recognition retry
Check load of nozzle during production
Production operation during transportation of a board
The feed amount is adjusted by teaching.
The height of a component is inspected after it is placed on a board.
8 Production (Pause)
Temporary stop at occurrence of “no components”
Temporary stop at occurrence of an error
Temporary stop at a component drop
The <Replenish at no-components> button is added to the temporary stop screen.
Temporary stop at occurrence of a recognition error
Pause (When Copla check fails)
Place without checking (When Copla check fails)
Put into trash box (When Copla check fails)
9 Production (NonStop)
Non-stop operation
Alternate
Set masterBank to Rear
Non-stop operation (MTC)
Alternate (MTC)
Non-stop operation (MTS)
Alternate (MTS)
Non-stop operation (DTS)
10 Production (cueing)
Perform component cueing
Number of detected pieces
Threshold value of “existence/non-existence of components” (OCC cueing)
Threshold value of “existence/non-existence of components” (3216) (OCC cueing)
11 Production (Others)
Set 0 for the default of the scheduled number of production PWBs.
Disable the step No. input of production condition.
No feed at occurrence of a pick error when the retry is set to 0.
Pre-pick feed
Use ceramic PWBs.
Do not detect the nozzle return posture.
Tray draw speed: Low Speed 2
Hide message on production start.
High-density placement
(Print offset forward) Short side of applicable component dimensions
12
Tracking/Inspection
(Inspection enabled)
Detection of tombstone
Component dimension check
Component orientation check
Pick position offset check
Nozzle protrusion check
Component mis-release check function
Only Colinearity checked (Properties checked)
Colinearity and Coplanarity check (Properties checked)

Part 2 Detailed Description of Each Function Chapter 7 Operation Option
7-3
No. Operation option group Option items
13
Tracking/Inspection
(Inspecting operation)
Check component release after the placement Z goes up.
Component existence check near the laser height of 0
Measure the component height at as start after “no components”
Verify inspection at a start after “no components”
Auto verification of component executed.
Perform component verification after pick tracking.
Execute verify inspection after splicing.
Splicing detection mis-pick count (times)
Splicing detection area (mm)
Change angle (Change angle of coplanarity check)
14
Tracking/Inspection
(Tracking operation)
Pick tracking at a start after “no components”
Feeder unit for pick tracking
Cursor shape at component pick tracking
15 Optimization
(Optimization disabled) When the pick data “auto selection” is set
(Optimization disabled) Change the pick data except auto selection.
(Optimization disabled) Change the ATC nozzle setup.
16 Tray
Pick start position (Tray/DTS/MTS)
Pick direction (Tray/DTS/MTS)
Pick start position (MTC)
Pick direction (MTC)
Enable Auto Compo. presence check of MTC

Part 2 Detailed Description of Each Function Chapter 7 Operation Option
7-4
7.2 General
Specify the operation options for general.
No Menu item
Description
Status
Operation and detailed explanation
1
Restriction of Explorer
Specify a function to restrict the use of Windows Explorer by
user level.
The use of Windows Explorer is restricted by user
level.
2
When the cover opens, OpKey is
invalidated.
Specify a function to disable all the switches other than the
STOP switch on the operation panel when the cover is opened.
When the cover is opened, all the switches on the
operation panel other than the STOP switch are
disabled.
3
Function for saving data when the system
shuts down.
Specify a function to save the read production program
information at the end of the desktop screen, and restore the
production program information at the next start.
The read production program information at the end
of the desktop screen is saved and the production
program information is restored at the nest start.
4 Enable the OpKey on the opposite side.
Specify a function to enable the START switch of the operation
panel on the side opposite to the panel being operated.
The START
switch of the operation panel on the side
opposite to the panel being operated is enabled.