RS-1_instruction manual.pdf - 第360页
Part 1 B asic O peration Chapter 4 Cr eating a Produc tion Progra m 4- 25 If you use a board w hose outer X - d imension exc eeds the regulated s i ze (650 m m) For a board wh ose outer X - dimensio n exceeds the regulat…

Part 1 Basic Operation Chapter 4 Creating a Production Program
4-24
When you press the <Detail Settings> button, the screen like one shown below appears.
Switch the tabs, “Mark 1,” “Mark 2” and “Mark 3.”
(1) Mark information
Information you set on the “BOC mark” screen appears here.
(2) Polarity
Specify whether to reverse the brightness of a shot image.
(3) Line width
Enter the line width of a mark. Note that the value entered here is not used for a shape that
does not require the line width.
(4) Detection margin
Enter the distance from the outer of a mark as the size of the detection frame used to
recognize a mark.
(5) Illumination Parameter
Enter the illumination value to be used when a mark is shot.
CAUTION
If the designed values of mark coordinates are provided (as CAD data),
never teach the X or Y coordinate.
Otherwise, all component placement coordinates will be shifted from the
designed values.
CAUTION
To prevent any accident causing injuries, never put your hand or head
inside the machine during teaching.

Part 1 Basic Operation Chapter 4 Creating a Production Program
4-25
If you use a board whose outer X-dimension exceeds the regulated size (650 mm)
For a board whose outer X-dimension exceeds the regulated size (650 mm), specify a
BOC mark (referred to as the first BOC mark hereinafter) in the range where a
component is to be placed when the board is clamped for the first time and another BOC
mark (referred to as the second BOC mark hereinafter) in the range where a component
is to be placed when the board is clamped for the second time.
Example: For a single-plane PWB that is transferred from left to right and whose size is
900 mm, enter the first BOC mark and the second BOC mark.
Board transport direction
① First component
placement area
② Second
component
placement area
Division position of a long-sized board

Part 1 Basic Operation Chapter 4 Creating a Production Program
4-26
4.3.3.4 Circuit Layout
Specify the circuit position and angle on this screen. Only when you select the “Non-matrix circuit”
radio button in the “PWB configuration” column of the “Dimension setup” tab, you can select these
items.
When you select the “Circuit Layout” tab located on the lower left corner of the “Dimension setup”
screen, the following screen appears.
(1) XY
Enter the position of the circuit origin viewed from the board origin.
(2) Angle
Enter the angle of a circuit.
(3) Skip
When you select to skip, the system does not place any component at all placement
positions of the corresponding circuit.
This item is displayed only when you select the <Used> button for the menu item “Circuit to
Be Placed” on the “Basic setting” screen.