Part 2 D etaile d Descript ion of E ach Functi on Chapter 8 Machine Set up 8- 20 Read ATC Data T o use an A TC, add information o n the A TC t o the syst em. The file for m at of A TC infor mation is as fol l ows: A TC *…

100%1 / 1058
Part 2 Detailed Description of Each Function Chapter 8 Machine Setup
8-19
Manually enter it.
- If registered nozzle data does not match or nozzle data has not yet been registered,
the Nozzle Data Registration screen appears. At this time register the appropriate
nozzle data from the USB Flash memory.
7) Various
When you press the <Open> button of <Select ATC>, the ATC selected at Device
selection can be opened. When you press the <Close> button, the ATC selected at
Device selection can be closed.
When you press the <ATC Operation> button of the Move Axiscolumn, the machine
moves heads to the ATC operation positions.
Vacuum value without nozzle
The system sets a vacuum value of each head on which no nozzle is attached, and checks
variations of vacuum values among heads.
If the value changes greatly when compared to the value set at filter replacement (about 10 % as
a reference), check and clean each head.
When you select the [Vacuum value without nozzle] command, the following screen appears.
(1) Setting items
No. Item Description
1
Change
filter
Obtains the vacuum value when no nozzle is attached. (Automatic obtaining only)
This setting item is used to judge the nozzle inspection and cleaning.
2
Nozzle
presence
check
Obtains the vacuum value to judge the nozzle attachment presence.
The obtained value is used as threshold value when the nozzle presence is judged
using the vacuum during origin return. (The value is updated even during origin
return.)
(2) How to set a nozzle
a) Acquire with the <ENTER> button
Press the <ENTER> button to get the vacuum value.
If a nozzle is attached to the head, the vacuum value is given after the nozzle has been
returned.
WARNING
When you click the <Exec> button, the axes move and the nozzle is
attached or removed. Before clicking the <Exec> button, be sure to
check to see if there is no one who operates the inside of the machine.
To avoid a risk of injury, do not place your hand in the machine, nor move
your face or head close to the machine.
Part 2 Detailed Description of Each Function Chapter 8 Machine Setup
8-20
Read ATC Data
To use an ATC, add information on the ATC to the system.
The file format of ATC information is as follows: ATC***_RS1.ini, where *** indicates the
corresponding ATC number, and the file is an ini file.
Follow the procedure below to register the ATC information to the machine.
When you select the [Read ATC data] command from the Filemenu, the Open Filescreen
appears.
Select the specified file, and then press the <Open> button. You have finished registered the
ATC information at this point.
When you press the <Cancel> button, no information is registered.
Check to see if the added ATC has been registered by the [ATC Setting].
Part 2 Detailed Description of Each Function Chapter 8 Machine Setup
8-21
ATC Setting
Set information on an ATC to be used.
When you select the [ATC Setting] command, the following screen appears.
CAUTION
Be sure to turn off the machine before attaching/detaching or replacing
an ATC plate.
After replacing an ATC plate with another one, be sure to make
settings of the ATC plate on this screen.
If you do not follow this procedure, a nozzle may be damaged.
(1) Setting items
No. Item Description
1
Selection of ATC to be used
Select an R-ATC to be used.
2
ATC Info.
Displays the list of registered ATCs and ATC information.
3
ATC discrimination
Sets the function for discriminating the mounted ATC to
ON/OFF.
4 ATC plate height check Sets the height check of the mounted ATC plate to ON/OFF.
(2) How to set
1) Select an R-ATC to be used from the combo box.
2) Specify whether to discriminate the ATC with the check box.
(3) ATC discrimination operation
1) When you enable the ATC discriminationcheck box, the system discriminates the ATC
at the following timing.
Except for during d) production below, when the system succeeds in discriminating the
ATC on each screen, it does not discriminate the ATC again unless you close the
screen.
a) Machine Setup
- When you change the ATC