RS-1_instruction manual.pdf - 第502页

Part 1 B asic O peration Chapter 4 Cr eating a Produc tion Progra m 4- 167 4.5.2 .3 Copy This comma nd store s data who se range is sel ected and highlight ed into the mem ory buf fer . T o paste the stored data i n anot…

100%1 / 1058
Part 1 Basic Operation Chapter 4 Creating a Production Program
4-166
4.5.2.2 Delete
Screen
Function
PWB
data
Basic setting screen This command cannot be used.
Dimension setup screen
This command can be executed only when the cursor is located in
one of the following fields: “PWB dimensions,” “Circuit
dimensions,” “First circuit position,” Circuit divide No.,” “Circuit pitch,
“BOC mark position No. 1” to “BOC mark position No. 3” and “Bad
mark position.”
Regardless of which field the cursor is located in, the “X” field or the
“Y” field, values entered in both of these fields are deleted when you
execute this command to delete data described above.
If the PWB data becomes incomplete due to the cut operation, you
cannot move to the “Placement” data screen, the “Component” data
screen or the “Pick” data screen. However, data entered on these
screens are not deleted, and when you create the PWB data
completely, they are displayed again.
Circuit Layout screen
This command deletes the selected record.
You cannot paste the deleted data. (The deleted data is not stored
in the memory buffer.)
Ex. Bad Mark screen
PWB Conveyor screen
This command can be used only when the cursor is located in one of
the following fields: “Ready In delay setting,” “Sensor delay,” “IN,”
“IN-STOP,” “OUT-STOP,” “OUT,” “Stop position correction (First
time),” “Stop position correction (Second time),” “Long-sized board
divide position,” “Default back height,” “Support table overstroke”
and “Support table overstroke (Ceramic).”
When you delete the data set in one of these fields, the initial value
is set for the corresponding field again.
Placeme
nt data
List screen
This command deletes the selected record.
You cannot paste the deleted data. (The deleted data is not stored
in the memory buffer.)
This command deletes a Placement data record only. It deletes a
Component data record linked to the deleted Placement data record
(as long as it does not refer to another Component data record).
Area mark screen
This command can delete data only when the corresponding mark
group is not used in Line Selection mode.
When a cell is selected, this command deletes also the coordinates
and data entered in the “TI” column both of which are related to the
cell where the focus is located.
In either case, you cannot paste the deleted data.
Area Bad Mark screen
Compone
nt data
List screen
You can delete only Component data not used to place a component
in Line Selection mode.
Form screen
This command cannot be used.
Pick data
List screen
This command can be used only if there are two or more Pick data
records for the same component, and the focus is located in one of
these records.
Otherwise, this menu command is dimmed.
There is always at least one Pick data record for one Component data
record on the list.
You cannot paste the deleted data with the [Paste] command. (It is not
stored in the memory buffer.)
Form screen
This command cannot be used.
If you used the sort function, you cannot select the [Delete] command.
Part 1 Basic Operation Chapter 4 Creating a Production Program
4-167
4.5.2.3 Copy
This command stores data whose range is selected and highlighted into the memory buffer.
To paste the stored data in another data, use the [Paste] command.
Screen
Function
PWB
data
Basic setting screen
This command cannot be used.
Dimension setup screen
Circuit Layout screen
Ex. Bad Mark screen
PWB Conveyor screen
Placeme
nt data
List screen
This command copies a record in which the focus is located
into the memory buffer.
You can paste the copied record with the [Paste] command.
Area mark screen
You cannot use this command in Browse mode.
This command copies the entire mark group in Line Selection
mode.
You can paste the copied data with the [Paste] command.
Area Bad Mark screen
You cannot use this command in Browse mode.
This command copies the entire mark group in Line Selection
mode.
You can paste the copied data with the [Paste] command.
Compone
nt data
List screen
This command cannot be used.
Form screen
Pick data
List screen
Form screen
Part 1 Basic Operation Chapter 4 Creating a Production Program
4-168
4.5.2.4 Paste
This command pastes data stored in the memory buffer with the [Cut] command or the [Copy]
command.
Screen
Function
PWB data
Basic setting screen
This command cannot be used.
Dimension setup
screen
Circuit Layout screen
Ex. Bad Mark screen
PWB Conveyor screen
Placement
data
List screen
You can select this command only if data is stored in the memory
buffer with the [Cut] command or the [Copy] command. Otherwise,
this command is dimmed.
After the data is pasted, the placement ID becomes “#.”
When you specify the “X Pitch” and the “Y Pitch,” you can use the
incremental copy function that copies data by adding or subtracting
a value of the placement position in the X direction and that in the Y
direction.
See the next page for how to operate this command in details.
Area mark screen
You can select this command only if data is stored in the memory
buffer with the [Copy] command. Otherwise, this command is
dimmed.
When this command is executed, the dialog box shown below is not
displayed (that is, the incremental copy function is not used), but the
copied data is pasted. If the paste destination line is not a blank
line, the message (OK/Cancel) appears on the screen. When you
select the <OK> button, the system overwrites the line with the
copied data.
(A blank line means a line on which no data is entered.)
Area Bad Mark screen
You can select this command only if data is stored in the memory
buffer with the [Copy] command. Otherwise, this command is
dimmed.
When this command is executed, the dialog box shown below is not
displayed (that is, the incremental copy function is not used), but the
copied data is pasted. If the paste destination line is not a blank
line, the message (OK/Cancel) appears on the screen. When you
select the <OK> button, the system overwrites the line with the
copied data.
(A blank line means a line on which no data is entered.)
Component
data
List screen
This command cannot be used.
Form screen
Pick data
List screen
Form screen
If you used the sort function, you cannot select the [Paste] command.