FUJI错误代码查询.pdf - 第10页
Remedy: Check Part data items 183~195. ------------------------------ Code: 1101031F Display: DVX1101031F Used by: CP652C Cause: The cam speed is not specified in Part data 196~208. Remedy: Check Part data items 196~208.…
Display: DVX11010316
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam speed is not specified in Part data 079~091 (CP4).
Remedy: Check Part data items 079~091. Enter an appropriate cam speed.
------------------------------
Code: 11010317
Display: DVX11010317
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam speed is not specified in Part data 091~104 (CP4).
Remedy: Check Part data items 091~104. Enter an appropriate cam speed.
------------------------------
Code: 11010318
Display: DVX11010318
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam speed is not specified in Part data 105~117 (CP4).
Remedy: Check Part data items 105~117. Enter an appropriate cam speed.
------------------------------
Code: 11010319
Display: DVX11010319
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam speed is not specified in Part data 118~130 (CP4).
Remedy: Check Part data items 118~130. Enter an appropriate cam speed.
------------------------------
Code: 1101031A
Display: DVX1101031A
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The cam speed is not specified in Part data 131~143 (CP4).
Remedy: Check Part data items 131~143. Enter an appropriate cam speed.
------------------------------
Code: 1101031B
Display: DVX1101031B
Used by: CP4-3,CP652C
Cause: The cam speed is not specified in Part data 144~156 (CP4).
Remedy: Check Part data items 144~156.
------------------------------
Code: 1101031C
Display: DVX1101031C
Used by: CP4-3,CP652C
Cause: The cam speed is not specified in Part data 157~169 (CP4).
Remedy: Check Part data items 157~169.
------------------------------
Code: 1101031D
Display: DVX1101031D
Used by: CP652C
Cause: The cam speed is not specified in Part data 170~182 (CP4).
Remedy: Check Part data items 170~182.
------------------------------
Code: 1101031E
Display: DVX1101031E
Used by: CP652C
Cause: The cam speed is not specified in Part data 183~195 (CP4).
第 9 页
Remedy: Check Part data items 183~195.
------------------------------
Code: 1101031F
Display: DVX1101031F
Used by: CP652C
Cause: The cam speed is not specified in Part data 196~208.
Remedy: Check Part data items 196~208.
------------------------------
Code: 11010320
Display: Claw may interfere with parts
Used by: QP3OF
Cause: When placing adjacent parts, a claw may interfere with parts that have already been placed.
Remedy: If a claw interferes with parts, change the claw used for placing the adjacent parts to type 2 or 3,
or set the claw乫s Q-axis pick-up rotation to 90 degrees.If no interference occurs, production can be
commenced using the existing recipe.The following examples are when this error is output without actual
interference occurring: *The height of the part to be placed is lower than that of adjacent parts already
placed. *The claw pick-up width for the adjacent part to be placed is set for clamping the inner section of a
part, and is narrower than the part outline.
------------------------------
Code: 11010401
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The item "Recipe_number" is out of range.
Remedy: After checking "Recipe_number" in MCS, transmit the program.
When the next production stage is the reflow oven, the MBID range is 1~30. In other words, when
Machine_type = 7 and
Machine_control_mode = 5 the Recipe_number = 1~30.
Otherwise, there are no special settings.
------------------------------
Code: 11010402
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The "Cvyr_speed" setting is incorrect.
Remedy: After checking "Cnvyr_speed" in MCS, transmit the program.
When the next production stage is the reflow oven, the MBID range is 1~42. In other words, when
Machine_type = 7 and
Machine_control_mode = 5, then Cnvyr_speed = 1~42.
Otherwise, there are on special settings.
------------------------------
Code: 11010403
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The "Oven_data" setting is incorrect.
Remedy: After checking "Oven_data" in MCS, transmit the program.
------------------------------
Code: 11010404
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The "Oven_check_data" setting is incorrect.
Remedy: After checking "Oven_check_data" in MCS, transmit the program.
------------------------------
第 10 页
Code: 11010405
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The "Pcb_x" setting is incorrect.
Remedy: After checking "Pcb_x" in MCS, transmit the program. When the next production stage is the
reflow oven, the MBID range is 80.00~508.00.
In other words, when Machine_type = 7 and Machine_control_mode = 5, then Pcb_x = 80.00~508.00.
Otherwise, there are no special settings.
------------------------------
Code: 11010406
Display:
Used by: QP242,QP201,QP202,QP203
Cause: The "Pcb_y" setting is incorrect.
Remedy: After checking "Pcb_y" in MCS, transmit the program. When using a board stacker, and is
communicating with the next production stage via an RS-232C, the MBID range is 50.00~457.00. That is,
when Machine_type = 5 or Machine_type = 7, and Machine_control_mode = 2~5, then Pcb_y =
50.00~457.00. Otherwise, there are no special settings.
------------------------------
Code: 11010407
Display: Same as code
Used by: GP551,GP6
Cause: The value specified at the item "Solder_supply_stroke" in the production program is outside the
acceptable range. The following input ranges are for the GP-641E series machines:
Greatest value:For machines with single squeegees.
New solder cutter mode:350 [mm]
Existing solder cutter mode:420 [mm]
For machines with double squeegees:460 [mm]
Minimum value:The values vary depending upon the solder supply speed.
Supply speed [mm/sec]Minimum value [mm]
40 -->60
80 -->80
120 -->120
160 -->200
200 -->240
Remedy: Input a value for the item "Solder_supply_stroke" that is within the permissible range.
------------------------------
Code: 11010408
Display: The position of global skip mark is incorrect.
Used by: IP3,QP242,QP201,QP202,QP203
Cause: The global skip mark has been set after a block skip mark set at block 1.
Remedy: Set the global skip mark in advance of the block skip mark.
------------------------------
Code: 11011000
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
Cause: X data is out of range (sequences 0001~0125).
Remedy: Check the X item in sequences 0001~0125.
------------------------------
Code: 11011001
Display:
Used by: CP3,CP4-1,CP4-2,CP5,IP2
第 11 页