FUJI错误代码查询.pdf - 第2125页

Used by: Cause: Invalid production program data has been downloaded. (i.e., The program with more than 100 slots is downloaded to XP141.) Remedy: Check to see if the slot number and stage number are correcet.etc. -------…

100%1 / 5282
------------------------------
Code: 2300300C
Display: Registration application information for another computer is registered on this license file. This
license file cannot be used.
Used by:
Cause: The license file registration application can only be performed at one computer. This license file
has already been used for license registration application at another computer.
Remedy: Check the license file classification number. If the license registration application process was
performed at an incorrect computer, apply to your Fuji sales representative for a new license file.
------------------------------
Code: 2300300D
Display: The license key for another computer is registered on this license file. This license file cannot be
used.
Used by:
Cause: A license file that contains the license key for another computer is being used.
Remedy: Check the license file classification number. If the license registration application process was
performed at an incorrect computer, apply to your Fuji sales representative for a new license file.
------------------------------
Code: 2300300E
Display: This license file is to be used for applying for new license registration. This file cannot be used on
a computer for which license registration has been completed.
Used by:
Cause: A license file that may only be used for new license registration is being used on a computer for
which license registration has been completed.
Remedy: Check the license file classification number. If the license registration application process was
performed at an incorrect computer, apply to your Fuji sales representative for a new license file.
------------------------------
Code: 2300300F
Display: The registration application information for this computer is registered on this license file. This
file cannot be used on a computer for which license registration has been completed.
Used by:
Cause: An unregistered license file is being used to perform the license registration application process
on a computer for which license registration has been completed. This error does not normally occur.
Remedy: If a registered license file is missing, apply to your Fuji sales representative for a new license file.
------------------------------
Code: 23003010
Display: An attempt was made to register the license by an account without administrator rights.Logon
using an account with administrator rights and register the license.
Used by:
Cause: An attempt was made to register the license by an account without administrator rights.
Remedy: Logon using an account with administrator rights and register the license.
------------------------------
Code: 23004001
Display: The communications port cannot be opened.
Used by:
Cause: The communications port cannot be opened because of some reason.
(i.e., The port is being used or broken.)
Remedy: Valid the communications port. (i.e., Close the application which is using the port. etc)
------------------------------
Code: 23004002
Display: The received data is corrupt.
第 2124 页
Used by:
Cause: Invalid production program data has been downloaded.
(i.e., The program with more than 100 slots is downloaded to XP141.)
Remedy: Check to see if the slot number and stage number are correcet.etc.
------------------------------
Code: 23004003
Display: Failed to receive the program.
Used by:
Cause: Failed to receive the program.
Remedy: Transmit the program from MCS/2 again.
------------------------------
Code: 23004004
Display: There is no response from MCS/2.
Used by:
Cause: There is no response from MCS/2 for MCS-X data requiring signal.
Setting for cables or ports may be incorrect.
Remedy: Check to see if the cables and ports are fine, then transmit the data from MCS/2 again.
------------------------------
Code: 23005007
Display: Select the log files in succession.
Used by:
Cause: The selected log files in the displayed list are not in succession.
Remedy: Select log files in succession.
------------------------------
Code: 23005008
Display: Unable to create an error code table.
Used by:
Cause: An error code table could not be created.
Remedy: Check whether the XP error code file exists
>>(Install folder)\System\XP_ENG.ERR
If this file does not exist, it is necessary to reinstall the software.
------------------------------
Code: 23005009
Display: A program necessary for totalisation does not exist. [File Name] Continue with calculation?
Used by:
Cause: The program required for log file tabulation does not exist in the specified folder.
Remedy: Obtain the required program from the XP machine, and save the program in the specified folder.
------------------------------
Code: 2300E001
Display: Range error [item name].
Used by:
Cause: A value which exceeds the permissible input range was entered.
Remedy: Enter a value within the permissible input range.
------------------------------
Code: 2300E002
Display: Number of permissible characters exceeded. [item name].
Used by:
Cause: The number of entered characters exceeded the permissible number.
Remedy: Select the setting item where the error occurred to display the permissible number of characters
(input range) at the bottom of the window, then revise the setting data so that this range is not exceeded.
------------------------------
第 2125 页
Code: 2300E003
Display: Data contains invalid characters. [item name].
Used by:
Cause: An illegal character was entered.
Remedy: Select the setting item where the error occurred to display the illegal character at the bottom of
the window, then revise the data accordingly.
------------------------------
Code: 2300E004
Display: No data exists. [item name].
Used by:
Cause: No setting has been specified.
Remedy: Specify a setting.
------------------------------
Code: 2300E102
Display: 'Position X' exceeds the range of the panel.
Used by:
Cause: The sequence data's X-coordinate is off the panel.
Remedy: Specify an X-coordinate which is within the panel size range.
------------------------------
Code: 2300E103
Display: 'Position Y' exceeds the range of the panel.
Used by:
Cause: The sequence data's Y-coordinate is off the panel.
Remedy: Specify an Y-coordinate which is within the panel size range.
------------------------------
Code: 2300E104
Display: Stage number has not been specified.
Used by:
Cause: The stage number has been set.
Remedy: Specify the stage number of the part to be mounted.
------------------------------
Code: 2300E105
Display: Slot number has not been specified.
Used by:
Cause: The slot number has not been set.
Remedy: Specify the slot number of the part to be mounted.
------------------------------
Code: 2300E106
Display: No data has been specified in stage number/slot number.
Used by:
Cause: No setting data exists for the stage number and slot number specified in the sequence data.
Remedy: Either specify settings for the stage number and slot number in the feeder setup data, or specify
a stage number and slot number for which setting data already exists.
------------------------------
Code: 2300E107
Display: Mark number has not been specified.
Used by:
Cause: The mark number in the fiducial mark reading sequence is set as "0".
Remedy: Specify a mark number setting other than "0".
------------------------------
Code: 2300E108
第 2126 页