Cause: When AUTO or STEP operation was entered, there was no sequence data in the program. Remedy: Download the program again to the IP machine. If the error occurs repeatedly, contact Fuji. -----------------------------…

100%1 / 5282
Cause: According to the conveyor end sensor there is a part on the conveyor.
Remedy: Due to a pickup mistake made by the IP machine, there is an unnecessary part on the conveyor.
In this case, remove the part.
------------------------------
Code: 11082460
Display: 11082460
Used by: MTU3,MTU5
Cause: The parts supply door at the back of the MTU is open.
Remedy: Close the door. In addition, check that the door is properly positioned.
------------------------------
Code: 11082490
Display: 11082490
Used by: MTU3,MTU5
Cause: The tray set sensor is off. A tray may have stopped mid-way through being ejected.
Remedy: Check that all of the trays in the column at the nozzle position where the error occurred are
correctly positioned. In addition, check that the sensor positions match the tray positions.
------------------------------
Code: 110824A0
Display: 110824A0
Used by: MTU3,MTU5
Cause: There is an unexpected part on the sub-nozzle. The part may have been placed there by the
operator.
Remedy: Remove the part on the sub-nozzle.
------------------------------
Code: 11083200
Display: Sequence number is out of range.
Used by: MTU4
Details: The sequence number is out of the valid range.
Cause:
Remedy: Ensure that the sequence number is between 1 and 4999.
------------------------------
Code: 11083210
Display: Device number is out of range.
Used by: MTU4
Details: The device number for the tray part is out of the valid range.
Cause:
Remedy: Ensure that the first digit in the device number is 1 for a tray unit on the right side, or 3 for a
tray unit on the left side. The second digit in the device number must be between 0 to 9, and the last digit
in the device number must be between 1 to 4.
------------------------------
Code: 11083220
Display: Terminate setting out of range.
Used by: MTU4
Details: A setting for a terminate sequence is out of the valid range.
Cause:
Remedy: The setting for the terminate sequence must either be ˇˇ(for a non terminate sequence) or
ˇˇ(for a terminate sequence).
------------------------------
Code: 110832F0
Display: Sequence Data Device Number Out of Range
Used by: MTU3,MTU4,MTU5
第 223 页
Cause: When AUTO or STEP operation was entered, there was no sequence data in the program.
Remedy: Download the program again to the IP machine. If the error occurs repeatedly, contact Fuji.
------------------------------
Code: 11083300
Display: Device no. out of range
Used by: MTU4
Cause: The slot number specified for tray parts is out of range.
Remedy: Check the ranges of the three digits in the device slot number. Input 1 (Right side) or 3 (Left
side) for the first digit (eg. 1??), a value between 0-9 (Shelf no.)for the second digit (eg. ?0?), and a value
between 1-4 (Tray compartment) for the third digit (eg. ??1).
------------------------------
Code: 11083301
Display: Next device no. out of range
Used by: MTU4
Cause: The next device slot number specified for tray parts is out of range.
Remedy: Check the three digits in the next device slot number. Input 1 (Right side) or 3 (Left side) for the
first digit (eg. 1??), a value between 0-9 (Shelf no.)for the second digit (eg. ?0?), and a value between 1-4
(Tray compartment) for the third digit (eg. ??1).
------------------------------
Code: 11083302
Display: Part height out of range
Used by: MTU4
Cause: The specified part height for tray parts is out of range.
Remedy: Input a value between 0 to 35.00(mm) in the Part data item Component Height.
------------------------------
Code: 11083310
Display: Cavity pitch (X) out of range
Used by: MTU4
Cause: The specified tray cavity pitch (X) is out of range.
Remedy: Input a value between 0 to 250.00(mm) in the Part data item Component Pitch (X).
------------------------------
Code: 11083311
Display: Cavity pitch (Y) out of range
Used by: MTU4
Cause: The specified tray cavity pitch (Y) is out of range.
Remedy: Input a value between 0 to 350.00(mm) in the Part data item Component Pitch (Y).
------------------------------
Code: 11083312
Display: Cavity quantity (X) out of range
Used by: MTU4
Cause: The specified cavity quantity (X) is out of range.
Remedy: Input a value between 0 to 50(cavities) in the Part data item Cavities (X).
------------------------------
Code: 11083313
Display: Cavity quantity (Y) out of range
Used by: MTU4
Cause: The specified cavity quantity (Y) is out of range.
Remedy: Input a value between 0 to 50(cavities) in the Part data item Cavities (Y).
------------------------------
Code: 11083314
Display: Tray pickup point (X) out of range
第 224 页
Used by: MTU4
Cause: The specified tray pickup point (X) is out of range.
Remedy: Input a value between -250.00 to 250.00(mm)in the Part data item Tray Pickup Pnt (X).
------------------------------
Code: 11083315
Display: Tray pickup point (Y) out of range
Used by: MTU4
Cause: The specified tray pickup point (Y) is out of range.
Remedy: Input a value between -250.00 to 250.00(mm)in the Part data item Tray Pickup Pnt (Y).
------------------------------
Code: 11083316
Display: Tray pickup point (Z) out of range
Used by: MTU4
Cause: The specified tray pickup point (Z) is out of range.
Remedy: Input a value between -12.8 to 12.7(mm)in the Part data item Tray Pickup Pnt (Z).
------------------------------
Code: 11083320
Display: First pickup point (X) out of range
Used by: MTU4
Cause: The specified first pickup point (X) for tray parts is out of range.
Remedy: Input a value between -250.00 to 250.00(mm)in the Part data item First Pickup Pnt (X).
------------------------------
Code: 11083321
Display: First pickup point (Y) out of range
Used by: MTU4
Cause: The specified first pickup point (Y) for tray parts is out of range.
Remedy: Input a value between -250.00 to 250.00(mm)in the Part data item First Pickup Pnt (Y).
------------------------------
Code: 11083330
Display: Sub-nozzle recovery count out of range
Used by: MTU4
Cause: The specified sub-nozzle recovery count is out of range.
Remedy: Input values between 0 to 255(times) for Pickup Retry (Proper data), Recovery Number (Status
data), and Recovery (Part data).
------------------------------
Code: 11083362
Display: Pickup offset (Z) out of range
Used by: MTU4
Cause: The specified pickup offset (Z) is out of range.
Remedy: Input a value between -12.7 to 12.7(mm) in the Part data item Pickup Height (Z).
------------------------------
Code: 11083370
Display: Tray thickness out of range
Used by: MTU4
Cause: The specified tray thickness is out of range.
Remedy: Input a value between 0 to 30.00(mm) in the Part data item Tray Thickness.
------------------------------
Code: 11083380
Display: Magazine rack pitch out of range
Used by: MTU4
Cause: The specified MTU rack pitch is out of range.