Cause: The conveyor shell could not start normally . Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control function could be damaged. ------------------------------ Code:…

100%1 / 5282
Display: Event error
Used by:
Cause: The event object became invalid.
Remedy: Reinstall software,if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201015
Display: Timeout
Used by:
Cause: The communication didn't complete to the conveyor control board with the host in the time.
Remedy: Resume operation after checking that the connection cable of a communication port has not
separated.
------------------------------
Code: 12201016
Display: CRC error
Used by:
Cause: An error has occurred during communication.
Remedy: Please reboot ,after checking connection of cable.
If this error cannot be corrected, the conveyor control board could be damaged.
------------------------------
Code: 12201017
Display: Retry over
Used by:
Cause: Communication wasn't established to the conveyor control board after retry.
Remedy: Please reboot ,after checking connection of cable.
If this error cannot be corrected, the conveyor control board could be damaged.
------------------------------
Code: 12201018
Display: Shared memory error
Used by:
Cause: The version of the modules may not be adjusted.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201019
Display: Command error
Used by:
Cause: After executing a command, it becomes extraordinary ending.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 1220101A
Display: Failed to send command.
Used by:
Cause: A command could not be send to the conveyor control board.
Remedy: After confirming whether or not the connection cable at the communication port doesn't come,
operation be resumed.
------------------------------
Code: 1220101F
Display: Failed to start shell.
Used by:
第 901 页
Cause: The conveyor shell could not start normally .
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201020
Display: Failed to terminate dll.
Used by:
Cause: The conveyor shell could not terminate normally.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201028
Display: Abnormal parameter.
Used by:
Cause: Because the parameter when using an API was an incorrect, the function could not be executed.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201032
Display: Communication port error.
Used by:
Cause: Conveyor control function wasn't possible to do the opening or the closing of the communication
port.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12201033
Display: Que error.
Used by:
Cause: The Que in conveyor control function was full.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the conveyor control
function could be damaged.
------------------------------
Code: 12202001
Display: Device communication error.
Used by:
Cause: The received data is incorrect data.
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12202002
Display: Queue buffer full.
Used by:
Cause: DxShell API function is called by mistake.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202003
Display: Association Suspended.
Used by:
第 902 页
Cause: Association was suspended because a feeder was removed.
Remedy: Reset the feeder on the device (PFU etc.).
------------------------------
Code: 12202010
Display: Parameter error.
Used by:
Cause: DxShell was set an invalid parameter.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202011
Display: No data.
Used by:
Cause: It was not possible to get data from DxShell.
Remedy: Reinstall software if this error cannot be corrected after reboot, because the DxShell could be
damaged.
------------------------------
Code: 12202020
Display: Device communication error.
Used by:
Cause: The time-out interval elapsed, and the response data did not receive.
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12202021
Display: Device communication error.
Used by:
Cause: It was not possible to do writing in Device communication port
Remedy: There's a possibility that the device(MFU,PFU,MTU etc) or the machine has a problem.
Please check the connection between the device and the machine.
Please change the devide to other device.
------------------------------
Code: 12203001
Display: Invalid Command
Used by:
Cause: The stepping motor controller detected an invalid command.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203002
Display: Axis error
Used by:
Cause: The stepping motor controller detected a command to a axis
that is unused.
Remedy: Replace stepping motor controller board with a new one if this error is not corrected after reboot,
because the controller board could be damaged.
------------------------------
Code: 12203003
Display: Syntax error
Used by: