FUJI错误代码查询.pdf - 第1515页

------------------------------ Code: 1D1D0011 Display: Same as code. Used by: Cause: The part's inclination is excessive. Remedy: Check the part supply direction. ------------------------------ Code: 1D1D0013 Displa…

100%1 / 5282
Cause: A sufficient number of leads could not be found.
Remedy: Check the lead quantity and the part supply direction. Lead thickness is critical to lead
detection. Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified
in the Part data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD
level.
------------------------------
Code: 1D1D000B
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D1D000C
Display: Same as code.
Used by:
Cause: A lead is too wide.
Remedy: Check the lead width. Lead thickness is critical to lead detection. Leads can be recognized if the
actual lead thickness is within [p/m]50% of the value specified in the Part data. A variety of errors may
occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D1D000D
Display: Same as code.
Used by:
Cause: A lead is too long.
Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D1D000E
Display: Same as code.
Used by:
Cause: A lead is too long.
Remedy: Check the lead length and the part supply direction. Lead thickness is critical to lead detection.
Leads can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part
data. A variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
------------------------------
Code: 1D1D000F
Display: Same as code.
Used by:
Cause: Processing error.
Remedy: Check the part's shape. Check for a missing part.
------------------------------
Code: 1D1D0010
Display: Same as code.
Used by:
Cause: The lead pitch is incorrect.
Remedy: Check the lead pitch and the lead quantity. Lead thickness is critical to lead detection. Leads
can be recognized if the actual lead thickness is within [p/m]50% of the value specified in the Part data. A
variety of errors may occur if this range is exceeded. Check the leads and the CCD level.
第 1514 页
------------------------------
Code: 1D1D0011
Display: Same as code.
Used by:
Cause: The part's inclination is excessive.
Remedy: Check the part supply direction.
------------------------------
Code: 1D1D0013
Display: Same as code.
Used by:
Cause: The lead quantity is set to 3, but only 2 leads could be found.
Remedy: Check the part's shape. Check the part supply direction. Check the Part data and the Device
data.
------------------------------
Code: 1D1D0014
Display: Same as code.
Used by:
Cause: The lead quantity is set to 2, but 3 leads were found.
Remedy: Check the part's shape. Check the part supply direction. Check the Part data and the Device
data.
------------------------------
Code: 1D1D8002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is to large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D1D8100
Display: Same as code.
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. setting in the Part data.
------------------------------
Code: 1D1D8110
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_pitch" parameter in the Part data.
Remedy: Set a value for the "Lead_pitch" parameter.
------------------------------
Code: 1D1D8111
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_width" parameter in the Part data.
Remedy: Set a value for the "Lead_width" parameter.
------------------------------
Code: 1D1D8112
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_x" parameter (the length of leads in the X direction) in
第 1515 页
the Part data.
Remedy: Set a value for the "Lead_length_x" parameter.
------------------------------
Code: 1D1D8113
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_y" parameter (the length of leads in the Y direction) in
the Part data.
Remedy: Set a value for the "Lead_length_y" parameter.
------------------------------
Code: 1D1D8114
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 1" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 1" parameter.
------------------------------
Code: 1D1D8115
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 0" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 0" parameter.
------------------------------
Code: 1D1D8120
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part
data.
Remedy: Set a value for the "Qty 0" parameter.
------------------------------
Code: 1D1D8121
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 1" parameter (the quantity of leads on the lower side) in the
Part data.
Remedy: Set a value for the "Qty 1" parameter.
------------------------------
Code: 1D1D8122
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 2" parameter (the quantity of leads on the right side) in the
Part data.
Remedy: Set a value for the "Qty 2" parameter.
------------------------------
Code: 1D1D8123
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 3" parameter (the quantity of leads on the upper side) in the
Part data.
Remedy: Set a value for the "Qty 3" parameter.
第 1516 页