FUJI错误代码查询.pdf - 第162页

Normally, set this to 5 for the machine and 6 for peripherals (this is normally set when the machine is shipped). ------------------------------ Code: 11022708 Display: Used by: Cause: Cell_status is set incorrectly. Rem…

100%1 / 5282
------------------------------
Code: 11022704
Display:
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GSP5,GP2,GP3,GP6,IP3,QP242,QP201,QP202,QP20
3,QP132
Cause: The Proper data item Reader port 2 is out of range (HELPS compatible).
Remedy: Check the Proper data item in MCS, and re-transmit it to the machine. When
change_over_mode is set to 5 or 25, this must be set. This command determines where the pattern code
reader or the code reader (upper surface) connect to the communication board or the LCU connector (the
connector number is 1~8). Do not use the same port numbers for different operations (i.e. avoid 1, 3,
Reader1_port and Command_line_port). Normally, set this to 4 for the machine and 5 for peripherals (this
is normally set when the machine is shipped).
------------------------------
Code: 11022705
Display:
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GSP5,GP2,GP3,GP6,IP3,QP242,QP201,QP202,QP20
3,QP132
Cause: The Proper data item Reader port 2 is the same as Command_line_port.
Remedy: Check the Proper data item in MCS, and re-transmit it to the machine. When
change_over_mode is set to 5 or 25, this must be set. This command determines where the pattern code
reader or the code reader (upper surface) connect to the communication board or the LCU connector (the
connector number is 1~8). Do not use the same port numbers for different operations (i.e. avoid 1, 3,
Reader1_port and Command_line_port). Normally, set this to 4 for the machine and 5 for peripherals (this
is normally set when the machine is shipped).
------------------------------
Code: 11022706
Display:
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GSP5,GP2,GP3,GP6,IP2,IP3,QP242,QP201,QP202,Q
P203,QP132
Cause: The Proper data item Code terminal port is out of range (HELPS compatible).
Remedy: Check the Proper data item in MCS, and re-transmit it to the machine. When
PCB_code_terminal is set to Use, this must be set. This command determines where the recovery code
terminal (code input) connects to the communication board or the LCU connector (the connector number
is 1~8). Do not use the same port numbers for different operations (i.e. avoid 1, 3, Reader1_port,
Reader2_port and Command_line_port). Normally, set this to 5 for the machine and 6 for peripherals (this
is normally set when the machine is shipped).
------------------------------
Code: 11022707
Display:
Used by: CP4-1,CP4-2,CP4-
3,CP5,CP6,CP6M,CP65,CP652C,CP642,CP643,GL541,GSP5,GP2,GP3,GP6,IP3,QP242,QP201,QP202,QP20
3,QP132
Cause: The Proper data items Code terminal port and Reader port 2 are the same as Command_line_port.
Remedy: Check the Proper data item in MCS, and re-transmit it to the machine. When
PCB_code_terminal is set to use, this must be set. This command determines where the recovery code
terminal (code input) connects to code terminal (code input) connects to the communication the
communication board or the LCU connector (the connector number is 1~8). Do not use the same port
numbers for different operations (i.e. avoid 1, 3, Reader1_port, Reader2_port and Command_line_port).
第 161 页
Normally, set this to 5 for the machine and 6 for peripherals (this is normally set when the machine is
shipped).
------------------------------
Code: 11022708
Display:
Used by:
Cause: Cell_status is set incorrectly.
Remedy: After checking Cell_status in MCS, re-transmit the Proper data.
"Unit cell" only exists on the ferris wheel feeder.
------------------------------
Code: 11022709
Display:
Used by: GP2,GP3,GP551,GP6,IP3,QP132
Cause: The Change_over_mode setting is incorrect.
Remedy: After checking the "change_over_mode" setting in MCS, re-transmit the Proper to the machine.
This is only effective when unit cell is in use. Do not use settings other than these. 0 = manual
terminate, 2 = pattern code reader, 4 = upper surface barcode reader, 5 = lower surface barcode reader
and 25 = barcode reader for both surfaces. For the Board Stacker, use 0 (manual terminate). For the
Ferris Wheel Feeder, use 4 (upper surface barcode reader).
------------------------------
Code: 1102270A
Display:
Used by: IP3,QP132
Cause: Command_line_status is set incorrectly.
Remedy: After checking the Command_line_status in MCS, re-transmit the Proper to the machine. LAN is
not currently recommended.
------------------------------
Code: 1102270B
Display:
Used by:
Cause: Terminal_type is set incorrectly.
Remedy: After checking the Terminal_type in MCS, re-transmit the Proper to machine. With Cell_status
at Unit, Change_over_mode at 2, 4, 5 or 25, and PCB_code_terminal at Use, this must be set. Choose
"CRX1200" or "HT." "VT-100" is not compatible.
------------------------------
Code: 1102270C
Display:
Used by: CP4-1,CP4-2,CP4-3,CP6,CP6M,CP65,CP652C,CP642,CP643
Cause: The Device Check Port, Command Line Port, Reader1 Port No., Reader2 Port No., Code Terminal
Port Proper data settings are set to the same number.
Remedy: Check the Device Check Port, Command Line Port, Reader1 Port No., Reader2 Port No., Code
Terminal Port Proper data settings in MCS, re-transmit the Proper data to the machine. Check the Device
Check Port, which must be set when using the Handy Terminal. Normally this is set to 1.
1 is the first connector from the top of the first communication board. This is normally set when the
machine is shipped. Command Line Port 2 is normally set to 2. Reader1 Port No. or Reader2 Port No. are
connected with the Pattern code reader, or the lower surface code reader. These are normally set to 3 and
4. Code Terminal Port is connected when the recovery terminal (code input) is used. This is normally set
to 5. 5 is the first connector from the top of the 2nd communication board.
------------------------------
Code: 1102270D
Display:
第 162 页
Used by: IP3
Cause: Conveyor Adj.Limit has no value specified even though the conveyor is being adjusted
automatically.
Remedy: Input an appropriate value in Proper data's 26.Conveyor Adj.Limit item.
------------------------------
Code: 1102270E
Display:
Used by: IP3
Cause: Conveyor Stop_offset has no value specified even though the conveyor is being adjusted
automatically.
Remedy: Input an appropriate value in Proper data's 27.Conveyor Stop_offset item.
------------------------------
Code: 1102270F
Display:
Used by: IP3
Cause: The value input in Conveyor Adj.Limit is smaller than the value input in Conveyor Stop_offset.
Remedy: Input a value in 26.Conveyor Adj.Limit which is larger than the value in 27.Conveyor
Stop_offset.
------------------------------
Code: 11022710
Display:
Used by: IP3
Cause: Conveyor adj. Timer has no value specified even though the conveyor is being adjusted
automatically.
Remedy: Input an appropriate value in Proper data's 28.Conveyor adj. Timer item.
------------------------------
Code: 11022711
Display:
Used by: IP3
Cause: Width Max Limit has no value specified.
Remedy: Input an appropriate value in Proper data's 29.Width Max Limit item.
------------------------------
Code: 11022712
Display:
Used by: IP3
Cause: Width Min Limit has no value specified.
Remedy: Input an appropriate value in Proper data's 30.Width Min Limit item.
------------------------------
Code: 11022713
Display:
Used by: IP3
Cause: The value input in Width Max Limit is smaller than the value input in Width Min Limit.
Remedy: Input a value in 29.Width Max Limit which is larger than the value in 30.Width Min Limit.
------------------------------
Code: 11022714
Display:
Used by: IP3,QP132
Cause: Terminal Type has no value specified.
Remedy: Input an appropriate value in Proper data's 56.Terminal Type item.
------------------------------
Code: 11022715
第 163 页