FUJI错误代码查询.pdf - 第1819页
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part data. Remedy: Set a value for the "Qty 0" parameter. ------------------------------ Code: 1D…
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D6B8100
Display: Same as code.
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. setting in the Part data.
------------------------------
Code: 1D6B8110
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_pitch" parameter in the Part data.
Remedy: Set a value for the "Lead_pitch" parameter.
------------------------------
Code: 1D6B8111
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_width" parameter in the Part data.
Remedy: Set a value for the "Lead_width" parameter.
------------------------------
Code: 1D6B8112
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_x" parameter (the length of leads in the X direction) in
the Part data.
Remedy: Set a value for the "Lead_length_x" parameter.
------------------------------
Code: 1D6B8113
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_y" parameter (the length of leads in the Y direction) in
the Part data.
Remedy: Set a value for the "Lead_length_y" parameter.
------------------------------
Code: 1D6B8114
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 1" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 1" parameter.
------------------------------
Code: 1D6B8115
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 0" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 0" parameter.
------------------------------
Code: 1D6B8120
Display: Same as code
Used by:
第 1818 页
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part
data.
Remedy: Set a value for the "Qty 0" parameter.
------------------------------
Code: 1D6B8121
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 1" parameter (the quantity of leads on the lower side) in the
Part data.
Remedy: Set a value for the "Qty 1" parameter.
------------------------------
Code: 1D6B8122
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 2" parameter (the quantity of leads on the right side) in the
Part data.
Remedy: Set a value for the "Qty 2" parameter.
------------------------------
Code: 1D6B8123
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 3" parameter (the quantity of leads on the upper side) in the
Part data.
Remedy: Set a value for the "Qty 3" parameter.
------------------------------
Code: 1D6B82??
Display: Same as code.
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B83??
Display: Same as code.
Used by:
Cause: The body is too short in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B84??
Display: Same as code.
Used by:
Cause: The body is too long in the Y direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B85??
Display: Same as code.
Used by:
Cause: The body is too short in the Y direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B88??
Display: Same as code.
第 1819 页
Used by:
Cause: A lead on the left side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B89??
Display: Same as code.
Used by:
Cause: A lead on the left side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B8A??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B8B??
Display: Same as code.
Used by:
Cause: A lead on the lower side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B8C??
Display: Same as code.
Used by:
Cause: A lead on the right side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B8D??
Display: Same as code.
Used by:
Cause: A lead on the right side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B8E??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too long. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B8F??
Display: Same as code.
Used by:
Cause: A lead on the upper side is too short. (The last two digits of the code indicate the lead number.)
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D6B90??
Display: Same as code.
Used by:
Cause: The lead pitch on the left side is too wide. (The last two digits of the code indicate the lead
number.)