Remedy: Check Part data. ------------------------------ Code: 2100742F Display: Skip device can not mount Used by: Cause: Unable to mount skip device. Remedy: This is a warning. There are too many devices, so the skip de…

100%1 / 5282
Used by:
Cause: Unable to open the index file.
Remedy: Re-install the software.
------------------------------
Code: 21007426
Display: Strategy file get error
Used by:
Cause: There is no strategy file.
Remedy: Re-install the software.
------------------------------
Code: 21007427
Display: Make not mark sequence
Used by:
Cause: Mark data was not created.
Remedy: This message occurs when there is a program without mark data.
------------------------------
Code: 21007428
Display: Prod file not write
Used by:
Cause: Unable to write to file.
Remedy: Check how much memory remains in the hard disk. If there is insufficient, delete unnecessary
files or execute the "H/D maintenance" function.
------------------------------
Code: 21007429
Display: Source file not found
Used by:
Cause: There is no source file.
Remedy: Check the source file name.
------------------------------
Code: 2100742A
Display: Source file open error
Used by:
Cause: Unable to open source file.
Remedy: Check the file.
------------------------------
Code: 2100742B
Display: Output file not found
Used by:
Cause: The output file does not exist.
Remedy: Re-start the MCS.
------------------------------
Code: 2100742C
Display: Output file open error
Used by:
Cause: Unable to open the output file.
Remedy: Check that the write protect function is not on.
------------------------------
Code: 2100742E
Display: Can not use Cartridge type
Used by:
Cause: Unable to use feeder type.
第 1934 页
Remedy: Check Part data.
------------------------------
Code: 2100742F
Display: Skip device can not mount
Used by:
Cause: Unable to mount skip device.
Remedy: This is a warning. There are too many devices, so the skip device cannot be mounted.
------------------------------
Code: 21007430
Display: Next device can not mount
Used by:
Cause: Unable to mount next device.
Remedy: This is a warning. There are too many devices, so the next device cannot be mounted.
------------------------------
Code: 21007431
Display: Can not used Tray type device
Used by:
Cause: Unable to use the tray type.
Remedy: Check Part data.
------------------------------
Code: 21007432
Display: Can not used Cartride type
Used by:
Cause: An unusable feeder type has been specified.
Remedy: Check Part data.
------------------------------
Code: 21007433
Display: No entry Machine type
Used by:
Cause: The input machine type is unsupported.
Remedy: Check the file. Upgrade the version if necessary.
------------------------------
Code: 21007434
Display: Program machine type unmatched
Used by:
Cause: The input file is not an IP2 program.
Remedy: Check the file.
------------------------------
Code: 21007435
Display: No entry Tray type
Used by:
Cause: The specified tray type cannot be used.
Remedy: Check Part data.
------------------------------
Code: 21007436
Display: New prodction file has no sequence data
Used by:
Cause: The new production program has no sequence data.
Remedy: Check the program's sequence data.
------------------------------
Code: 21007437
第 1935 页
Display: PT file device station range over
Used by:
Cause: The Permanent Set Table device station is out of range.
Remedy: Check the PST file device number.
------------------------------
Code: 21007438
Display: Input program file name is too long
Used by:
Cause: Input program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 21007439
Display: Output program file name is too long.
Used by:
Cause: The output program filename is too long.
Remedy: Check the filename.
------------------------------
Code: 2100743A
Display: Permanent Set Table name is too long
Used by:
Cause: The Permanent Set Table name is too long.
Remedy: Check the filename.
------------------------------
Code: 2100743B
Display: Illegal format at Machine type table
Used by:
Cause: The machine type table format is illegal.
Remedy: Re-install the software.
------------------------------
Code: 2100743C
Display: Can't used Station_No. to Tray_type_device
Used by:
Cause: Tray parts have been specified at non-tray device numbers.
Remedy: If the device number is a fixed device, check that the device locations at the input program are
correct. If the device number is in the Permanent Set Table, check that the device locations in the
Permanent Set Table are correct. If the device locations are in the base program, check that the device
locations in the base program are correct.
------------------------------
Code: 2100743D
Display: Status does not Tray_type_device
Used by:
Cause: Tray parts have been specified for non-tray device positions.
Remedy: If the device number is a fixed device, check that the device locations at the input program are
correct. If the device number is in the Permanent Set Table, check that the device locations in the
Permanent Set Table are correct. If the device locations are in the base program, check that the device
locations in the base program are correct.
------------------------------
Code: 2100743E
Display: "No entry Machine name"
Used by:
Cause: A machine name has not been entered in the "Type" parameter in the "Sep_data" section of the
第 1936 页