FUJI错误代码查询.pdf - 第850页

Remedy: Press RESET and then restart operation. ------------------------------ Code: 1207F?70 Display: "SCU?(PMC?,ICM) Error Code:********" "FX-Axis Comm Error" Used by: QP242 Cause: Cannot communicat…

100%1 / 5282
Display: "SCU?(ICM,PMC?) Error Code:********"
"FX-Axis Servo Alarm Controller Processing"
Used by: QP242
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
------------------------------
Code: 1207F?67
Display: "SCU?(ICM,PMC?) Error Code:********"
"FX-Axis Servo Alarm Transmission Timeout"
Used by: QP242
Cause: The command's first character was not input within the specified time (30 ms).
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?68
Display: "SCU?(ICM,PMC?) Error Code:********"
"FX-Axis Servo Alarm Transmission Timeout"
Used by: QP242
Cause: The time between characters exceeds 100 ms.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?69
Display: "SCU?(ICM,PMC?) Error Code:********"
"FX-Axis Servo Alarm Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?6A
Display: "SCU?(ICM,PMC?) Error Code:********"
"FX-Axis Servo Alarm Axis Alarm Still Occuring"
Used by: QP242
Cause: A command was received before the machine was reset.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?6B
Display: "SCU?(ICM,PMC?) Error Code:********"
"FX-Axis Servo Alarm Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
第 849 页
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?70
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Comm Error"
Used by: QP242
Cause: Cannot communicate with the servo unit.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check that the servo unit is properly connected.
------------------------------
Code: 1207F?71
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Memory Failure"
Used by: QP242
Cause: Memory cannot be secured.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 1207F?72
Display: "SCU?(PMC?,ICM) Error Code:********"
"The FX-Axis Servo is OFF or an alarm is active."
Used by: QP242
Cause: The FX-axis servo is off or an alarm is active.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: If the FX-axis servo is off, check that the servo controller is being supplied with power. If an
alarm is active, clear the alarm and restart operation.
------------------------------
Code: 1207F?73
Display: "SCU?(PMC?,ICM) Error Code:********"
"A FX-axis servo parameter have not been set."
Used by: QP242
Cause: Check the parameters for the FX-axis.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Set the FX-axis servo parameters, supply power and restart operation.
------------------------------
Code: 1207F?74
Display: "SCU?(PMC?,ICM) Error Code:********"
"Cancellation by FX-Axis stop command."
Used by: QP242
Cause: Axis operation terminated because a separate error occurred during communication.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?75
Display: "SCU?(PMC?,ICM) Error Code:********"
"Error prior to FX-Axis Encorder Counter Operation"
第 850 页
Used by: QP242
Cause: The machine attempted to take an encoder count before the current count had been confirmed.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?76
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Encorder Counter Overflow"
Used by: QP242
Cause: During axis movemen,the maximum counter value was exceeded.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?77
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Encorder Counter Recieving Error"
Used by: QP242
Cause: An error occurred at the FX-axis servo controller when receiving data.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?78
Display: "SCU?(PMC?,ICM) Error Code:********"
"Disconnected FX-Axis"
Used by: QP242
Cause: FX-axis is not connected.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Check the RB controller cable connections.
------------------------------
Code: 1207F?79
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Servo Controller Timeout"
Used by: QP242
Cause: The FX-axis timed out.
"?" indicates the module number (QP2).
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
Code: 1207F?7A
Display: "SCU?(PMC?,ICM) Error Code:********"
"FX-Axis Servo Controller Busy"
Used by: QP242
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the module number (QP2)
"****" indicates the error code.
Remedy: Press RESET and then restart operation.
------------------------------
第 851 页