FUJI错误代码查询.pdf - 第203页
Cause: abolished Remedy: abolished ------------------------------ Code: 1107A?06 Display: abolished Used by: QP122 Cause: abolished Remedy: abolished ------------------------------ Code: 1107A?07 Display: abolished Used …
machine, the problem may be caused by faulty hardware such as the servo amps or servo boards.
------------------------------
Code: 1107900E
Display: RB Servo Limit Error
Used by: QP242,QP201,QP132
Cause: The maximum or minimum position for the axis controlled by the Robustshin servo motor has
been exceeded. Alternatively, something may be obstructing the overtravel sensor for that axis.
Remedy: Return the axis in question to a position within the maximum and minimum range using the
inching keys and check those values.
------------------------------
Code: 1107900F
Display: RB Servo Limit Check Error
Used by: QP242,QP201,QP132
Cause: The Robustshin servo motor attempted to move its axis to a position outside the range of its
maximum and minimum values.
Remedy: The Robustshin servo motor cannot move an axis outside the maximum or minimum range.
Check these maximum and minimum values. Alternatively, check the position to which the Robustshin
servo motor is attempting to move the axis.
------------------------------
Code: 1107A?01
Display: PID Error:A?01
Used by: QP132
Cause: Data carrier reading time out.
"?" represents the ID number where the error curred. Approach station: 1-5, Mark read module: 6,
Landing station: 7, Pallet loader: 8.
Remedy: It may not be possible to read the pallet ID in some cases if the position the pallet stopped in is
not suitable. If this is the case, move the pallet so it is positioned suitably to have its ID read.
Alternatively, the problem may be caused by faulty ID related hardware. Change to a different pallet, and
use the ID reading command to check this.
------------------------------
Code: 1107A?02
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?03
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?04
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?05
Display: abolished
Used by: QP122
第 202 页
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?06
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?07
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?08
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?11
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?12
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?14
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?70
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?71
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
第 203 页
Code: 1107A?72
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?7A
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?7C
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107A?7D
Display: abolished
Used by: QP122
Cause: abolished
Remedy: abolished
------------------------------
Code: 1107B100
Display: An error device was reported.
Used by:
Cause: Verifier reported that a feeder for which the error status has not yet been cleared still exists on
the device table.
Remedy: Check the error status of the feeder at the device check panel. Perform verification as normal
using the Handy Terminal or reregister the FIDL and DID association data to clear the error status.
------------------------------
Code: 1107BF01
Display:
Used by:
Cause: Version numbers do not match.
Remedy: None.
------------------------------
Code: 1107BF05
Display:
Used by:
Cause: Syntax check error.
Remedy: An error occurred during communication. Re-establish communication.
------------------------------
Code: 1107BF06
Display:
Used by:
Cause: Positioning D number error.
Remedy: This is an inching axis range error. Input a correct inching axis number.
------------------------------
Code: 1107BF07
第 204 页