FUJI错误代码查询.pdf - 第797页
Cause: Z-axis servopack positioning timeout. (value replacing "?" is module number; error code appears in place of asterisks) (value replacing "??" is module number)(QP132) Remedy: Check whether somet…
(value replacing "??" is module number)(QP132)
Remedy: Check the program coordinates and the Proper data values.
------------------------------
Code: 1207A?10
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Overcurrent/PWT Overheat" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Either excessive current or overheating of the power transistor has been detected in the Z-axis
servopack.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Servopack replacement may be necessary.
------------------------------
Code: 1207A?11
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Short Circuit" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A short circuit has been detected in the Z-axis servopack.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether one of the motor power wires (U, V, or W) is shorted to the ground (E).
------------------------------
Code: 1207A?20
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Software Limit (+)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Z-axis servopack software limit has been exceeded in the (+) direction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The movement target position exceeds the limit values specified in the Proper data. Check the
movement target value and the Proper data values.
------------------------------
Code: 1207A?21
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Software Limit (-)" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Z-axis servopack software limit has been exceeded in the (-) direction.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: The movement target position exceeds the limit values specified in the Proper data. Check the
movement target value and the Proper data values.
------------------------------
Code: 1207A?22
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Positioning Time-out" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
第 796 页
Cause: Z-axis servopack positioning timeout.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, or whether the axis action has become
extremely heavy.
------------------------------
Code: 1207A?23
Display: "ICM (PMC?,SCU?) Error Code:********" (QP2)
"Power to the servo amp has been cut" (QP2)
Used by: QP202,QP203,QP242
Cause: The power to the servo amp has been cut. ? is the module number. "****" is the error code.
Remedy: Check around the power source for problems such as loose terminal blocks etc.
------------------------------
Code: 1207A?2A
Display: PM?? ERROR Code: ********
"Z-axis down time out"
Used by: QP132
Cause: Z-axis descent timed out for nozzle A.
The question marks represent the module number, and the asterisks represent the error code.
Remedy: Check that axis movement is not being interfered with, and that movement is normal along the
entire length of the axis.
------------------------------
Code: 1207A?2B
Display: PM?? ERROR Code: ********
"Z-axis down time out"
Used by: QP132
Cause: Z-axis descent timed out for nozzle B.
The question marks represent the module number, and the asterisks represent the error code.
Remedy: Check that axis movement is not being interfered with, and that movement is normal along the
entire length of the axis.
------------------------------
Code: 1207A?2C
Display: PM?? ERROR Code: ********
"Z-axis down time out"
Used by: QP132
Cause: Z-axis descent timed out for nozzle C.
The question marks represent the module number, and the asterisks represent the error code.
Remedy: Check that axis movement is not being interfered with, and that movement is normal along the
entire length of the axis.
------------------------------
Code: 1207A?2D
Display: PM?? ERROR Code: ********
"Z-axis down time out"
Used by: QP132
Cause: Z-axis descent timed out for nozzle D.
The question marks represent the module number, and the asterisks represent the error code.
Remedy: Check that axis movement is not being interfered with, and that movement is normal along the
entire length of the axis.
------------------------------
Code: 1207A?2E
Display: PM?? ERROR Code: ********
第 797 页
"Z-axis down time out"
Used by: QP132
Cause: Z-axis descent timed out for nozzle E.
The question marks represent the module number, and the asterisks represent the error code.
Remedy: Check that axis movement is not being interfered with, and that movement is normal along the
entire length of the axis.
------------------------------
Code: 1207A?2F
Display: PM?? ERROR Code: ********
"Z-axis down time out"
Used by: QP132
Cause: Z-axis descent timed out for nozzle F.
The question marks represent the module number, and the asterisks represent the error code.
Remedy: Check that axis movement is not being interfered with, and that movement is normal along the
entire length of the axis.
------------------------------
Code: 1207A?30
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Regenerative Error" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Regenerative error in the Z-axis servopack.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Servopack replacement may be necessary.
------------------------------
Code: 1207A?31
Display: "PMC?(ICM,SCU?) Error Code:********" (QP2)
"Excessive Deviation" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: Excessive deviation in the Z-axis servopack.
(value replacing "?" is module number; error code appears in place of asterisks)
(value replacing "??" is module number)(QP132)
Remedy: Check whether something is interfering with the axis, or whether the axis action has become
extremely heavy. Check whether the motor power wires (U, V, and W) or the encoder wire have
becomebroken or short-circuited. Servopack replacement may be necessary.
------------------------------
Code: 1207A?3A
Display: PM?? ERROR Code: ********
"Z-axis up time out"
Used by: QP132
Cause: Z-axis ascent timed out for nozzle A.
The question marks represents the module number, and the asterisks represent the error code.
Remedy: Check that axis movement is not being interfered with, and that movement is normal along the
entire length of the axis.
------------------------------
Code: 1207A?3B
Display: PM?? ERROR Code: ********
"Z-axis up time out"
Used by: QP132
第 798 页