FUJI错误代码查询.pdf - 第661页

LD_ERR 12066A05 Used by: QP132 Cause: There was a failure with the data carrier page toggle write function. Remedy: Make sure that circulation is being carried out correctly. Check the connection between the data carrier…

100%1 / 5282
Code: 1206690D
Display: PFU Unclamp Error [1206690D]
Used by: QP132
Cause: The PFU's unclamping operation (X035-X03B: PFU? UNCLP) did not finish in the given time.
Remedy: Check operation using I/O commands and adjust if necessary.
------------------------------
Code: 12066A00
Display: ID_GET_PAGE_ERR
LD_ERR 12066A00
Used by: QP132
Cause: The data carrier page data could not be read.
Remedy: Make sure that circulation has been carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A01
Display: ID_TRN_MDL_ERR
LD_ERR 12066A01
Used by: QP132
Cause: There was a communication failure with the command that controls the number of write times.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A02
Display: ID_PAGE_OVER_ERR
LD_ERR 12066A02
Used by:
Cause: The number of data carrier write times has been exceeded.
Remedy: Replace the pallet data carrier.
------------------------------
Code: 12066A03
Display: ID_MDL_RESP_ERR
LD_ERR 12066A03
Used by: QP132
Cause: There was an error with the response from the command that controls the number of write times.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A04
Display: ID_READ_DATA_ERR
LD_ERR 12066A04
Used by: QP132
Cause: The first page of data of the data carrier could not be read.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A05
Display: ID_COPY_DATA_ERR
第 660 页
LD_ERR 12066A05
Used by: QP132
Cause: There was a failure with the data carrier page toggle write function.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A06
Display: ID_NEXT_PAGE_ERR
LD_ERR 12066A06
Used by: QP132
Cause: There was a failure with the page data write function.
Remedy: Make sure that circulation is being carried out correctly. Check the connection between the
data carrier controller and the head and the connection between the controller and the machine's
communication connector.
------------------------------
Code: 12066A07
Display: CARRIER DATA ERROR
ID Reader Error: 12066A07
Used by: QP132
Cause: The pallet's carrier data at the landing station is corrupt.
Remedy: The pallet's data carrier at the landing station has corrupted information. Remove all pallets
and reload them.
------------------------------
Code: 12066A08
Display: No carrier at landing station.
ID Reader Error: 12066A08
Used by: QP132
Cause: A carrier is at the landing station when it should not be there or, when a carrier is expected for
the loading of a pallet, there is no carrier present.
Remedy: Check that the connection between the landing station head and ID controller, as well as the
connection between the ID controller and the machine data port, is good. When a pallet is present when
none should be, remove and reload all pallets.
------------------------------
Code: 12066A09
Display: JEDEC tray type error!
Used by: QP301
Cause: A JEDEC tray feeder of the wrong type has been attached.
Remedy: Attach a JEDEC tray feeder of the correct type.
------------------------------
Code: 12066A0A
Display: Lifter plate error!
Used by: QP301
Cause: An atempt was made to unclamp the package with the lifter plate in place.
Remedy: Remove the lifter plate.
------------------------------
Code: 12066A0B
Display: Nozzle Position Error
Used by: QP301
Cause: Nozzle is not set to the right holder.
Remedy: Check the nozzle positions and make changes as required.
第 661 页
------------------------------
Code: 12066B00
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Measurement error. The acquired deviation is outside the acceptable range.
Remedy: Check for damage to the cylinder head, wiring errors, electro-pneumatic regulator errors, and
pressure measurement unit errors.
------------------------------
Code: 12066B01
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Compensation cannot be calculated due to a precise pressure Proper data error. Precise pressure
calibration may not have been performed.
Remedy: Perform precise pressure calibration for the target holder(s).
------------------------------
Code: 12066B02
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Precise pressure controller load range error. Load instruction cannot be issued.
Remedy: Correct the maximum and minimum load range values in the machine configuration file, and
then calibrate the pressure.
------------------------------
Code: 12066B03
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: Incorrect value issued to the pressure controller.
Remedy: Perform precise pressure calibration for the target holder(s).
------------------------------
Code: 12066B04
Display: Precise pressure control error
Used by: NP-2, QP-3
Cause: An error occurred at the precise pressure controller.
Remedy: Reboot the machine, and inspect the pressure controller if the problem persists.
------------------------------
Code: 12066B05
Display: Pressure measurement unit error.
Used by: NP-2, QP-3
Cause: An error occurred at the pressure measurement unit.
Remedy: Reboot the machine, and inspect the pressure measurement unit if the problem persists.
------------------------------
Code: 12066B06
Display: RADDS error
Machine type: QP3
Used by:
Cause: The Machine memory condition differs to that of RADDS.
Remedy: Remove the die using the die removal command.
------------------------------
Code: 12066B07
Display: RADDS error
Machine type: QP3
Used by: