Display: Same as code. Used by: Cause: No leads could be found. Remedy: Check the lead length and width, and the image acquisition conditions. ------------------------------ Code: 1D35404C Display: Same as code. Used by:…
------------------------------
Code: 1D354044
Display: Same as code.
Used by:
Cause: The part size is not within [p/m]10% of the values indicated by the Part data.
Remedy: Check the Part data. Also, check for soiling of the nozzle or the part. Make sure that the correct
part is being processed.
------------------------------
Code: 1D354045
Display: Same as code.
Used by:
Cause: The parts inclination is not within [p/m]15%, or the part is not rectangular.
Remedy: Check the Part data. Also, check for soiling of the nozzle or the part. Make sure that the correct
part is being processed.
------------------------------
Code: 1D354046
Display: Same as code.
Used by:
Cause: This error occurs when the image quality is unstable (due to soiling of the nozzle or the part),
when the part shape is inappropriate (e.g. when there are protrusions or concavities), or when there is a
large discrepancy between Part data values and the actual values for the part.
Remedy: Check for soiling of the nozzle or the part. Make sure that the correct part is being processed.
------------------------------
Code: 1D354047
Display: Same as code.
Used by:
Cause: This error occurs when the image quality is unstable (due to soiling of the nozzle or the part),
when the part shape is inappropriate (e.g. when there are protrusions or concavities), or when there is a
large discrepancy between Part data values and the actual values for the part.
Remedy: Check for soiling of the nozzle or the part. Make sure that the correct part is being processed.
------------------------------
Code: 1D354048
Display: Same as code.
Used by:
Cause: No leads could be found.
Remedy: Check the part's shape and the Part data.
------------------------------
Code: 1D354049
Display: Same as code.
Used by:
Cause: The lead pitch is not within the allowable range.
Remedy: Check the part's shape.
------------------------------
Code: 1D35404A
Display: Same as code.
Used by:
Cause: The part could not be found. The part's outline could not be identified.
Remedy: Check the Part data and the manner in which the part is picked up. Check the image
acquisition conditions.
------------------------------
Code: 1D35404B
第 1668 页
Display: Same as code.
Used by:
Cause: No leads could be found.
Remedy: Check the lead length and width, and the image acquisition conditions.
------------------------------
Code: 1D35404C
Display: Same as code.
Used by:
Cause: The part's inclination has exceeded 15%, or the four sides are not equally inclined.
Remedy: Check the manner in which the part is picked up, and the part's shape.
------------------------------
Code: 1D358002
Display: Same as code.
Used by:
Cause: The machine failed to pick up a part. The nozzle being used is to large for the part. The part
cannot be identified in the vision processing image.
Remedy: Supply the part. If this error occurs even though a part has been picked up, use a smaller
nozzle for the part. Reduce the CCD level so that the part image becomes visible.
------------------------------
Code: 1D358100
Display: Same as code.
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. setting in the Part data.
------------------------------
Code: 1D358110
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_pitch" parameter in the Part data.
Remedy: Set a value for the "Lead_pitch" parameter.
------------------------------
Code: 1D358111
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_width" parameter in the Part data.
Remedy: Set a value for the "Lead_width" parameter.
------------------------------
Code: 1D358112
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_x" parameter (the length of leads in the X direction) in
the Part data.
Remedy: Set a value for the "Lead_length_x" parameter.
------------------------------
Code: 1D358113
Display: Same as code
Used by:
Cause: No value has been set for the "Lead_length_y" parameter (the length of leads in the Y direction) in
the Part data.
Remedy: Set a value for the "Lead_length_y" parameter.
------------------------------
第 1669 页
Code: 1D358114
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 1" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 1" parameter.
------------------------------
Code: 1D358115
Display: Same as code
Used by:
Cause: No value has been set for the "Body_size 0" parameter (the body length in the X direction) in the
Part data.
Remedy: Set a value for the "Body_size 0" parameter.
------------------------------
Code: 1D358120
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 0" parameter (the quantity of leads on the left side) in the Part
data.
Remedy: Set a value for the "Qty 0" parameter.
------------------------------
Code: 1D358121
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 1" parameter (the quantity of leads on the lower side) in the
Part data.
Remedy: Set a value for the "Qty 1" parameter.
------------------------------
Code: 1D358122
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 2" parameter (the quantity of leads on the right side) in the
Part data.
Remedy: Set a value for the "Qty 2" parameter.
------------------------------
Code: 1D358123
Display: Same as code
Used by:
Cause: No value has been set for the "Qty 3" parameter (the quantity of leads on the upper side) in the
Part data.
Remedy: Set a value for the "Qty 3" parameter.
------------------------------
Code: 1D3582??
Display: Same as code.
Used by:
Cause: The body is too long in the X direction.
Remedy: Check the part's shape and supply direction. Check the Part data and the Device data.
------------------------------
Code: 1D3583??
Display: Same as code.
Used by:
第 1670 页