FUJI错误代码查询.pdf - 第678页

Code: 120684A9 Display: TZ-axis: Option WDC error! Used by: QP3,NP2 Cause: Remedy: Check that the MECHATROLINK interface unit is correctly attached to the servo amplifier.If correct installation does not rectify the prob…

100%1 / 5282
------------------------------
Code: 120684A1
Display: TZ-axis: Absolute encoder clear and multiturn limit setting error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120684A2
Display: TZ-axis: Encoder communication error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120684A3
Display: TZ-axis: Encoder parameter error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120684A4
Display: TZ-axis: Encoder echo-back error.
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120684A5
Display: TZ-axis: Multiturn limit disagreement.
Used by: QP3,NP2
Cause:
Remedy: Check that the correct value is entered for the Pn205 servo parameter.
------------------------------
Code: 120684A6
Display: TZ-axis: Position deviation overflow error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120684A7
Display: TZ-axis: No option error!
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK interface unit is correctly attached to the servo amplifier.If
correct installation does not rectify the problem, replace the MECHATROLINK interface unit.
------------------------------
Code: 120684A8
Display: TZ-axis: Option time-out error!
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK interface unit is correctly attached to the servo amplifier.If
correct installation does not rectify the problem, replace the MECHATROLINK interface unit.
------------------------------
第 677 页
Code: 120684A9
Display: TZ-axis: Option WDC error!
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK interface unit is correctly attached to the servo amplifier.If
correct installation does not rectify the problem, replace the MECHATROLINK interface unit.
------------------------------
Code: 120684AA
Display: TZ-axis: WDT error!
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120684AB
Display: TZ-axis: Communication error!
Used by: QP3,NP2
Cause:
Remedy: Check that the MECHATROLINK communications cable between the MTU controller and servo
amplifier is connected correctly.
------------------------------
Code: 120684AC
Display: TZ-axis: Servo response error!
Used by: QP3,NP2
Cause:
Remedy: Replace the servo amplifier.
------------------------------
Code: 120684AD
Display: TZ-axis: Servo back initial access error!
Used by: QP3,NP2
Cause:
Remedy: Replace the servo amplifier.
------------------------------
Code: 120684AE
Display: TZ-axis: Servo back WDC error!
Used by: QP3,NP2
Cause:
Remedy: Replace the servo amplifier.
------------------------------
Code: 120684AF
Display: TZ-axis: Command uncompleted.
Used by: QP3,NP2
Cause: Servo amp error.
Remedy: Reset the servo amp.
------------------------------
Code: 120684B0
Display: TZ-axis: Power line open phase.
Used by: QP3,NP2
Cause:
Remedy: Check the servo amplifier power cable connection.
------------------------------
Code: 12068500
第 678 页
Display: TY-axis servo amp error.
Used by: QP3,NP2
Cause: Servo amp initialization error. No response from servo amp.
Remedy: Cut and resupply the power to the MTU.
------------------------------
Code: 12068530
Display: TY-axis: Overtravel error (software limit) in the +direction.
Used by: QP3,NP2
Cause:
Remedy: Check if the correct data has been input for machine calibration data item Max Limit Position
TY.
------------------------------
Code: 12068531
Display: TY-axis: Overtravel error (software limit) in the -direction
Used by: QP3,NP2
Cause:
Remedy: Check if the correct data has been input for machine calibration data item Min Limit Position
TY.
------------------------------
Code: 12068532
Display: TY-axis: Insufficient servo power.
Used by: QP3,NP2
Cause: A movement command was issued while the power supply to the servos was off.
Remedy: Reset to supply power to the servos.
------------------------------
Code: 12068533
Display: TY-axis: Positioning time-out error.
Used by: QP3,NP2
Cause:
Remedy: Check the servo parameters and the wiring between the servo amps and the servo motors.
------------------------------
Code: 12068534
Display: TY-axis: Positioning travel distance limit error.
Used by: QP3,NP2
Cause:
Remedy: Check the axis traveling distances specified in the production program.
------------------------------
Code: 12068535
Display: TY-axis: File type change error!
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 12068536
Display: TY-axis: Filter constant change error!
Used by: QP3,NP2
Cause:
Remedy:
------------------------------
Code: 12068537
Display: TY-axis: Origin specification error!
第 679 页