FUJI错误代码查询.pdf - 第1974页

comment field of the PST file. The feeder type will be determined based on the Part data Remedy: Use the editor to edit the PST file, and enter a feeder type in the "Device_name" parameter for the device number…

100%1 / 5282
Display: Skip device mount error
Used by:
Cause: There are too many skipped devices at the station, so the devices cannot be arranged.
Remedy: Skipped devices cannot be overwritten to an output file.
------------------------------
Code: 21007836
Display: Next device mount error
Used by:
Cause: There are too many next devices at the station, so the devices cannot be arranged.
Remedy: Next devices cannot be overwritten to an output file.
------------------------------
Code: 21007837
Display: Can not make mount sequence
Used by:
Cause: The order of mount sequences cannot normally be changed.
Remedy: None.
------------------------------
Code: 21007838
Display: Strategy file read error
Used by:
Cause: Strategy file read error.
Remedy: Reinstall the system.
------------------------------
Code: 21007839
Display: Cannot make mark sequence
Used by:
Cause: Cannot create mark sequences.
Remedy: Reinstall MCS.
------------------------------
Code: 2100783A
Display: Output file has not sequence
Used by:
Cause: Output file has no sequences.
Remedy: Specify an input program with sequences.
------------------------------
Code: 2100783B
Display: No entry machine name
Used by:
Cause: FIP3 is not registered in Part data's separator data.
Remedy: Register the FIP3 and add FIP3 data in Part data's separator.
------------------------------
Code: 2100783C
Display: "Not get queue position"
Used by:
Cause: This is a system error. It should not occur under normal circumstances.
Remedy: Stop the FIP-III optimizer, then reexecute.
------------------------------
Code: 2100783D
Display: "Undefined cartridge name for device in PT file"
Used by:
Cause: The feeder type cannot be determined, because the feeder type has not been entered in the device
第 1973 页
comment field of the PST file. The feeder type will be determined based on the Part data
Remedy: Use the editor to edit the PST file, and enter a feeder type in the "Device_name" parameter for the
device number in question.
------------------------------
Code: 2100783E
Display: "Feeder position in PT file is out of range"
Used by:
Cause: A feeder position specified as fixed in the PST file is outside the feeder station range. The device
comment in question will be separated as a non-fixed feeder.
Remedy: Specify a feeder position within the feeder station's range.
------------------------------
Code: 2100783F
Display: "There is insufficient space for a feeder in PT file"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred when the feeder width was checked against the end of the station. The feeder in question will be
separated as a non-fixed feeder.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007840
Display: "Space between feeders in PT file is insufficient"
Used by:
Cause: An attempt was made to allocate the feeder in question as specified by the PST file, but an error
occurred due to interference between feeders.
Remedy: Change the PST specification number of the feeder in question.
------------------------------
Code: 21007900
Display: Illegal parameter option
Used by:
Cause: An illegal character has been set as a start parameter.
Remedy: Check the start option and then re-start the machine.
------------------------------
Code: 21007901
Display: Message file read error
Used by:
Cause: The message file cannot be read.
Remedy: Re-install the message file.
------------------------------
Code: 21007902
Display: CRT event link error
Used by:
Cause: The CRT event cannot be linked.
Remedy: Reboot the MCS.
------------------------------
Code: 21007903
Display: Input file open error
Used by:
Cause: The input file cannot be opened.
Remedy: Edit the input file using the editor command.
------------------------------
Code: 21007904
第 1974 页
Display: Input file read error
Used by:
Cause: The input file cannot be read.
Remedy: Edit the input file using the editor command.
------------------------------
Code: 21007905
Display: Input file not found
Used by:
Cause: The input file was not found.
Remedy: Check the file name.
------------------------------
Code: 21007906
Display: Output file open error
Used by:
Cause: The space remaining on the hard disk may be insufficient.
Remedy: Delete unnecessary files from the hard disk.
------------------------------
Code: 21007907
Display: Output file write error
Used by:
Cause: The space remaining on the hard disk may be insufficient.
Remedy: Delete unnecessary files from the hard disk.
------------------------------
Code: 21007908
Display: Base program file open error
Used by:
Cause: The base program cannot be opened.
Remedy: Edit the base program using the editor command.
------------------------------
Code: 21007909
Display: Base program file read error
Used by:
Cause: The base program cannot be read. Edit the base program using the editor command.
Remedy: Re_edit the base program.
------------------------------
Code: 2100790A
Display:
Used by:
Cause: Base program file not found.
Remedy: Check the file name.
------------------------------
Code: 2100790B
Display: PST file open error
Used by:
Cause: The permanent set table cannot be opened.
Remedy: Edit the permanent set table using the editor command.
------------------------------
Code: 2100790C
Display: PST file read error
Used by:
Cause: The permanent set table cannot be read.
第 1975 页