Code: 11079?04 Display: RB Servo Error :9?04 Used by: GP551,GP6,QP132 Cause: A protocol error (a parity error, framing error, or an overrun error) occurred while receiving data. The RB unit ALM light is on. "?"…

100%1 / 5282
Check that the size entered in Body_size is the same as the actual body size. Make Coplanarity item
4.Y_offset bigger so that the measurement is done farther from the edge of the leads. Check that the
encoder cable is properly connected to the CyberOptics board. Check that the sensor cable is properly
connected to both the sensor and the CyberOptics board. The cable should be connected to jumper 1. If
the error recurs, turn off the power and start again.
------------------------------
Code: 1107500A
Display: LLL system is executing another command.
Used by: IP3
Cause: Another measurement command was executed while the LLL board was performing a coplanarity
check.
Remedy: Switch off the machine and then re-start it.
------------------------------
Code: 1107500B
Display: Leads do not exist on part being inspected.
Used by: IP3
Cause: There were no leads on the part on which the coplanarity check was performed.
Remedy: The coplanarity check cannot be performed on parts which have no leads. Check that the Part
data settings are correct.
------------------------------
Code: 11079?01
Display: RB Servo Error :9?01
Used by: GP551,GP6,QP132
Cause: Processing cannot be performed during an emergency stop.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: After releasing the emergency stop button, restart operation.
------------------------------
Code: 11079?02
Display: "RB Servo Error: 9?02"
Used by: GP551,GP6,QP132
Cause: A timeout occurred during communication with the RB servo unit.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Restart processing after resetting. This error may also be caused by breaks in cables, or by
malfunctions of the communication board or the RB controller.
------------------------------
Code: 11079?03
Display: RB Servo Error :9?03
Used by: GP551,GP6,QP132
Cause: It is not possible to execute a new command while still executing another command.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Press RESET and then restart operation.
------------------------------
第 199 页
Code: 11079?04
Display: RB Servo Error :9?04
Used by: GP551,GP6,QP132
Cause: A protocol error (a parity error, framing error, or an overrun error) occurred while receiving data.
The RB unit ALM light is on.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Press RESET and then restart operation. It is possible that the cable, communication board, or
RB controller is faulty.
------------------------------
Code: 11079?05
Display: RB Servo Error :9?05
Used by: GP551,GP6,QP132
Cause: The specified axis is not connected.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Check the RB controller cable connections.
------------------------------
Code: 11079?06
Display: "RB Servo Error: 9?06"
Used by: GP551,GP6,QP132
Cause: A timeout occurred during communication with the RB servo unit. The ALM lamp on the RB unit
will light when this error occurs. (If the new RB unit is being used, an amp driver alarm will be indicated.)
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Restart processing after resetting. (If the new RB unit is being used, check the amp driver power
supply.)
------------------------------
Code: 11079?07
Display: "RB Servo Error: 9?07"
Used by: GP551,GP6,QP132
Cause: Command execution was not possible because the RB controller was busy processing.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Restart processing after resetting. The STOP signal of the RB interface unit may be stuck open.
------------------------------
Code: 11079?08
Display: RB Servo Error :9?08
Used by: GP551,GP6,QP132
Cause: The command's first character was not input within the specified time (30 ms).
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
第 200 页
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: If the problem persists after clearing the error using the RESET button, or restarting the
machine, the problem may be caused by faulty hardware such as the servo amps or servo boards.
------------------------------
Code: 11079?09
Display: RB Servo Error :9?09
Used by: GP551,GP6,QP132
Cause: The time between characters exceeds 100 ms.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: If the problem persists after clearing the error using the RESET button, or restarting the
machine, the problem may be caused by faulty hardware such as the servo amps or servo boards.
------------------------------
Code: 11079?0A
Display: RB Servo Error :9?0A
Used by: GP551,GP6,QP132
Cause: Memory cannot be secured.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Switch the power off and then on, then restart operation.
------------------------------
Code: 11079?0B
Display: RB Servo Error :9?0B
Used by: GP551,GP6,QP132
Cause: A command was received before the machine was reset.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Press RESET and then restart operation.
------------------------------
Code: 11079?0C
Display: RB Servo Error :9?0C
Used by: GP551,GP6
Cause: During axis movemen,QP132t the maximum counter value was exceeded.
"?" indicates the location of the error: 0 for the controller, 1 for the MX axis, 2 for the MYL axis, 3 for
the MYR axis, and 4 for the SSD axis.(GP551,GP6)
"?" indicates the location of the error: 0 for the controller, and 1, ( PO axis ) for the respective axis
numbers.(QP132)
Remedy: Press RESET and then restart operation.
------------------------------
Code: 11079?0D
Display: RB Driver Error [11079?0D]
Used by: QP132,GP551,GP6
Cause: An alarm is occurring from the RB servo's driver. This error does not usually occur.
Remedy: If the problem persists after clearing the error using the RESET button, or restarting the