FUJI错误代码查询.pdf - 第1135页

Remedy: The clamper must be closed in order to move the XY-table to the middle loading position. Check to see if the out-carrier clamper is closed. If closed, and if this error occurs anyway, adjust the sensor mounting p…

100%1 / 5282
Code: 15040410
Display: Out-carrier advance limit error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier has deviated from the advance limit position.
Remedy: Check the out-carrier position. If the out-carrier is at the prescribed advance limit position,
check the out-carrier's advance limit sensor. If the out-carrier is not at the prescribed advance limit
position, move the out-carrier to its advance limit position.
------------------------------
Code: 15040411
Display: Out-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier close limit sensor failed to switch on. An out-carrier close was executed to advance
the out-carrier from its retract limit position but the open confirmation sensor at the advance limit side
failed to switch off within the prescribed period of time. Alternatively, an out-carrier close was executed to
retract the out-carrier from its advance limit position but the open confirmation sensor at the retract limit
side failed to switch off within the prescribed period of time.
Remedy: Check to see if the out-carrier close operation has occurred correctly. Also verify that the out-
carrier close limit sensor is mounted at the correct position.
------------------------------
Code: 15040412
Display: Out-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier open limit sensor failed to switch on.
Remedy: Check to see if the out-carrier open operation has occurred correctly. Also verify that the out-
carrier open limit sensor is mounted at the correct position.
------------------------------
Code: 15040414
Display: Out-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier cannot be advanced, as there is a risk of interference with the panel on the out-lifter
(because it is not known if there is a panel on the out-carrier).
Remedy: Remove the panel from the out-lifter.
------------------------------
Code: 15040415
Display: Out-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier cannot be retracted, as there is a risk of interference between the panel on the out-
carrier and the panel on the out-lifter.
Remedy: Remove the panel from the out-lifter.
------------------------------
Code: 15040416
Display: Out-carrier operation disabled.
Used by: CP-732E, CP-742ME, CP-742E
Cause: Out-carrier cannot be retracted, as there is a risk of interference with the panel on the out-lifter
(because it is not known if there is a panel on the out-carrier).
Remedy: Remove the panel from the out-lifter.
------------------------------
Code: 15040417
Display: Out-carrier clamp error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier clamper's close limit (clamp limit) sensor failed to switch on.
第 1134 页
Remedy: The clamper must be closed in order to move the XY-table to the middle loading position. Check
to see if the out-carrier clamper is closed. If closed, and if this error occurs anyway, adjust the sensor
mounting position.
------------------------------
Code: 15040418
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carriers advance limit and retract limit sensors are both off.
Remedy: Move the out-carrier to either the advance limit or the retract limit position. If this error still
occurs, adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their
mounting positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040419
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier's advance limit and retract limit sensors are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041A
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's advance limit side are both off.
Remedy: Move the clamper to either the open limit or the close limit position. If this error still occurs,
adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their mounting
positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041B
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's advance limit side are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041C
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's retract limit side are both off.
Remedy: Move the clamper to either the open limit or the close limit position. If this error still occurs,
adjust the sensor mounting positions. If the sensors still fail to switch on after adjusting their mounting
positions, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041D
Display: Out-carrier sensor error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The clamper open limit and close limit sensors at the out-carrier's retract limit side are both on.
Remedy: Adjust the sensor mounting positions. If the sensors still fail to switch off, there may be a
sensor wiring problem or a sensor failure.
------------------------------
Code: 1504041E
Display: Out-carrier panel conveyance error.
第 1135 页
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensors 1 and 2 (X0CC, X0CD) failed to switch on even though 2 panel s
were loaded from the XY-table. In systems with a panel present memory, the panel present/absent status
on the out-carrier was checked, but the out-carrier 1 panel sensor and the out-carrier 2 panel sensor
could not verify the presence of a panel .
Remedy: Check the panel conveyance condition. If there is no panel on the out-carrier, use the out-
carrier unclamp command to open the out-carrier. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 1504041F
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensor 1 (X0CC) failed to switch on even though 1 panel was loaded from
the XY-table. In systems with a panel present memory, the panel present/absent status on the out-carrier
was checked, but the out-carrier 1 panel sensor could not verify the presence of a panel .
Remedy: Check the panel conveyance condition. If there is no panel on the out-carrier, use the out-
carrier unclamp command to open the out-carrier. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040420
Display: Out-carrier panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-carrier panel sensor failed to switch on even though a panel was conveyed from the XY-
table to the out-carrier.
Remedy: Check to see if the panel has been conveyed properly to the our-carrier. If the error persists
even though the panel conveyance has occurred properly, adjust the sensor mounting position.
------------------------------
Code: 15040421
Display: Out-lifter logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter UP and DOWN limit sensors are both off.
Remedy: Move the out-lifter to either the UP or DOWN limit position, and if the error still occurs, readjust
the sensor mounting position. If the sensor still fails to switch on even after adjusting its mounting
position, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040422
Display: Out-lifter logic error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter UP and DOWN limit sensors are both on.
Remedy: Readjust the sensor mounting position. If the sensor still fails to switch off even after adjusting
its mounting position, there may be a sensor wiring problem or a sensor failure.
------------------------------
Code: 15040423
Display: Out-lifter panel conveyance error.
Used by: CP-732E, CP-742ME, CP-742E
Cause: The out-lifter panel sensors 1 and 2 (X0C7, X0C9) failed to switch on even though 2 panel s were
loaded from the out-carrier.
Remedy: Check the panel conveyance condition. If this error occurs even though panel s are being
conveyed properly, check to see if the sensor is operating correctly.
------------------------------
Code: 15040424
第 1136 页