------------------------------ Code: 1207E?07 Display: "SCU?(ICM,PMC?) Error Code:********" (QP2) "PMC Reply Time Out" (QP2) Used by: QP242,QP201,QP202,QP203 Cause: A timeout occurred while waiting fo…

100%1 / 5282
"IOCountMachConstrctMismatch" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: The I/O quantity does not match the machine configuration.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: This error should not occur under normal conditions.
------------------------------
Code: 1207E?02
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Sig From Next Stge Time Out" (QP2)
PM?? ERROR Code:******** (QP132)
Used by: QP242,QP201,QP202,QP203,QP132
Cause: A timeout occurred while waiting for the next stage.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that boards are smoothly sent on to the next stage. Make sure that the board arrival
check sensor at the next stage is functioning normally.
------------------------------
Code: 1207E?03
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Loading Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A timeout occurred while waiting to load a board.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure that boards are smoothly sent from the previous stage smoothly. Make sure that the
board arrival check sensor is functioning normally.
------------------------------
Code: 1207E?04
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Exists" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There is a board on the conveyor.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the board that is on the conveyor. Make sure that the board arrival check sensor is
functioning normally.
------------------------------
Code: 1207E?05
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Thermal Tripped" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Thermal relay has been tripped.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Reset the thermal relay.
------------------------------
Code: 1207E?06
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Reject Parts Conveyor Full" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The reject conveyor is full.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Remove the rejected parts from the reject conveyor. Make sure that the reject conveyor full
check sensor is functioning normally.
第 815 页
------------------------------
Code: 1207E?07
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"PMC Reply Time Out" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A timeout occurred while waiting for a response from the PMC.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Make sure the ARCNET cable is not broken. Check the PMC for problems.
------------------------------
Code: 1207E?08
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Robust Controller Error" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: Robust controller error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Clear the robust controller error.
------------------------------
Code: 1207E?09
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Flux Controller Error" (QP2)
Used by: QP242
Cause: Flux controller error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Clear the flux controller error.
------------------------------
Code: 1207E?0A
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Safety Door Open" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The machine has executed an emergency stop because a safety door is open.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Close the safety door.
------------------------------
Code: 1207E?0B
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Specified D No Incorrect" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: A nonexistent device number has been specified, resulting in a device number error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Specify the correct device number.
------------------------------
Code: 1207E?0C
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Feeder OFF Signal" (QP2)
No Feeder OFF Signal(NP2,QP3)
Used by: QP242,QP201,QP202,QP203,NP2,QP3
Cause: A timeout has occurred while waiting for supply setup completion, resulting in a feeder error.
(value replacing "?" is module number; error code appears in place of asterisks)(QP2)
A timeout has occurred while waiting for supply setup completion, resulting in a feeder
error.(NP2,QP3)
Remedy: Check that the air supply is connected properly, or that the sequencer is operating correctly.
第 816 页
------------------------------
Code: 1207E?0D
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Machine Stop(SCU Error)" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The command could not be executed because the SCU was stopped due to an error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Clear the SCU error, press the RESET switch, and restart the machine.
------------------------------
Code: 1207E?0E
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"No Specified Axis Exists" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The specified axis does not exist.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Specify the desired axis using a proper axis number.
------------------------------
Code: 1207E?0F
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"MTU Not Ready/MTU Locked" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The conditions for tray unit activation where not met. (The tray unit is locked.)
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to clear the tray lock status.
------------------------------
Code: 1207E?10
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"TY Axis Not at Origin" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: The shuttle (TY-axis) is not at the origin position.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Use inching or another method to set the shuttle at the origin position.
------------------------------
Code: 1207E?11
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Board Doed Not Exit" (QP2)
Used by: QP242,QP201,QP202,QP203
Cause: There is no board on the conveyor.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Set a board on the conveyor. Make sure that the board arrival check sensor is functioning
normally.
------------------------------
Code: 1207E?12
Display: "SCU?(ICM,PMC?) Error Code:********" (QP2)
"Nozzle Positioning NG" (QP2)
Used by: QP242
Cause: Index-type nozzle positioning error.
(value replacing "?" is module number; error code appears in place of asterisks)
Remedy: Rotate the nozzle to the positioning complete position. Make sure that the nozzle positioning
check sensor is functioning normally.
------------------------------