Used by: Cause: There are too many leads (set in PDG). Remedy: Check that the nozzle is not dirty, that there are no foreign particles on the part, and that the correct part is being analyzed. ---------------------------…

100%1 / 5282
Cause: The lead length is too long (longer than the PDG setting by over 10%).
Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that
the correct part is being picked.
------------------------------
Code: 1D060014
Display:
Used by:
Cause: The lead length is not long enough (shorter than the PDG setting by over 10%).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060015
Display:
Used by:
Cause: The lead length is too long (longer than the PDG setting by over 10%).
Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that
the correct part is being picked.
------------------------------
Code: 1D060016
Display:
Used by:
Cause: The lead length is not long enough (shorter than the PDG setting by over 10%).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060017
Display:
Used by:
Cause: The lead length is too long (longer than the PDG setting by over 10%).
Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that
the correct part is being picked.
------------------------------
Code: 1D060018
Display:
Used by:
Cause: The lead length is not long enough (shorter than the PDG setting by over 10%).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060019
Display:
Used by:
Cause: The lead length is too long (longer than the PDG setting by over 10%).
Remedy: Check that the nozzle is not dirty and that there are no foreign particles on the part. Check that
the correct part is being picked.
------------------------------
Code: 1D06001A
Display:
Used by:
Cause: The shape of the part was strange. Vision processing cannot take a good image.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D06001B
Display:
第 1306 页
Used by:
Cause: There are too many leads (set in PDG).
Remedy: Check that the nozzle is not dirty, that there are no foreign particles on the part, and that the
correct part is being analyzed.
------------------------------
Code: 1D06001C
Display:
Used by:
Cause: There are too many leads (compared with the PDG setting).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060020
Display:
Used by:
Cause: There are too many leads (compared with the PDG setting).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060021
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060022
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060023
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060024
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060025
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060026
Display:
Used by:
Cause: The corner lead cannot be found.
第 1307 页
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060027
Display:
Used by:
Cause: The corner lead cannot be found.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060041
Display:
Used by:
Cause: The lead cannot be found (the pitch is too wide or there are too few leads).
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D060060
Display:
Used by:
Cause: The lead cannot be found, or the corner lead is bent.
Remedy: The nozzle is dirty, there is foreign matter on the parts, or the wrong parts are being used.
------------------------------
Code: 1D068002
Display:
Used by:
Cause: The part was not picked. The nozzle used with this part is too large. Vision processing could not
detect any part.
Remedy: Re-supply parts. If parts were picked and this error occurred, make the nozzle smaller. Lower
the CCD level so that parts can be detected.
------------------------------
Code: 1D068100
Display:
Used by:
Cause: This Computer Vision No. is not supported.
Remedy: Check the Computer Vision No. in Part Data.
------------------------------
Code: 1D068110
Display:
Used by:
Cause: Lead_pitch (pitch between the lead spaces) in Part data has not been specified.
Remedy: Specify Lead_pitch in Part data.
------------------------------
Code: 1D068111
Display:
Used by:
Cause: Lead_width in Part data has not been specified.
Remedy: Specify Lead_width in Part data.
------------------------------
Code: 1D068112
Display:
Used by:
Cause: Lead_length_x in Part data has not been specified.
Remedy: Specify Lead_length_x in Part data.