FUJI错误代码查询.pdf - 第561页

Used by: CP652C Cause: When the pallet is moving from the in-setup station to the in-position: 1. The in-setup station cylinder has not reached its extended position in the 10 seconds allowed. 2. The input status for eac…

100%1 / 5282
Cause: The lower limit detection sensor for the ST11 cylinder has not turned on.
Remedy: The action of the ST11 cylinder has deteriorated.Check the cylinder as prescribed in the
maintenance manual. Please note that the component may not have been placed by ST11 (i.e., it may be
missing).
------------------------------
Code: 12054083
Display: "Air Cylinder Cycle Alarm SQG Open/Close"
Used by: GP551,GP6
Cause: Squeegee opening or closing required longer than the specified time.
Remedy: Check the squeegee open check sensor (X078:SQG OPEN CHK) and the squeegee closed check
sensor (X079:SQG CLOSE CHK).
------------------------------
Code: 12054084
Display: "Air Cylinder Cycle Alarm top Cleaner Connected"
Used by: GP551,GP6
Cause: Insertion of the notch required longer than the specified time.
Remedy: Use I/O commands to check the sensor (GSP5, GP6).
------------------------------
Code: 12054085
Display: "Air Cylinder Cycle Alarm Head Lock"
Used by: GP551
Cause: Insertion of the notch required longer than the specified time.
Remedy: Use I/O commands to check the sensor.
------------------------------
Code: 12054086
Display: "Air Cylinder Cycle Alarm Top Cleaner Lock"
Used by:
Cause: Insertion of the notch required longer than the specified time.
Remedy: Use I/O commands to check the sensor.
------------------------------
Code: 12054087
Display: "Pallet Transport ERROR UP Elevator -> SETUP_ST. IN"
Used by: CP652C
Cause: A pallet transport error occured between the up-elevator and the in-setup station. The cause of
the error may be one of the following.
1. The pallet in-cylinder has not reached its extended position in the 10 seconds allowed.
2. The input status for each of the sensors after the pallet in-cylinder arrived at its extended position is as
follows:
- The retract position sensor is on.
- The up-elevator pass-through sensor (between up-elevator <-> in-setup station) is detecting a pallet or is
being obstructed.
- The up-elevator pallet sensor is detecting a pallet.
- The setup station pallet sensor is not detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the pallet in-cylinder sensor (X088) and the retract position sensor (X089).
Check the input status of the up-elevator pallet pass-through sensor (X085).
Check the input status of the up-elevator pallet sensor (X084).
Check the input status of the in-setup station pallet sensor (X077).
------------------------------
Code: 12054088
Display: "Pallet Transport ERROR SETUP_ST. IN -> IN Pos."
第 560 页
Used by: CP652C
Cause: When the pallet is moving from the in-setup station to the in-position:
1. The in-setup station cylinder has not reached its extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the in-setup station cylinder has arrived at its extended
position, is as follows:
- The retract position (extended position) sensor is on.
- The in-setup station pallet pass-through sensor (between in-position <-> in-setup station) is detecting a
pallet.
- The in-setup station pallet sensor is detecting a pallet.
- The in-position pallet sensor is not detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X072) for the in-setup station cylinder and the
retract position sensor (X073).
Check the input status of the in-setup station pallet pass-through sensor (X06E).
Check the input status of the in-setup station pallet sensor (X077).
Check the input status of the in-position pallet sensor (X046).
------------------------------
Code: 12054089
Display: "Pallet Transport ERROR IN Pos -> SETUP_ST. IN."
Used by: CP652C
Cause: When the pallet is moving from the in-position to the in-setup station:
1. The in-setup station cylinder has not reached its retract position in the 10 seconds allowed.
2. The input status for each of the sensors, after the in-setup station cylinder has arrived at its retract
position, is as follows:
- The extended position sensor is on.
- The in-setup station pallet pass-through sensor (between in-position <-> in-setup station) is not
detecting a pallet.
- The in-setup station pallet sensor is not detecting a pallet.
- The in-position pallet sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X072) for in-setup station cylinder and the retract
position sensor (X073).
Check the input status of the in-setup station pallet pass-through sensor (X06E).
Check the input status of the in-setup station pallet sensor (X077).
Check the input status of the in-position pallet sensor (X046).
------------------------------
Code: 1205408A
Display: "Pallet Transport ERROR SETUP_ST. OUT -> OUT Pos."
Used by: CP652C
Cause: A pallet transport error occured between the out-setup station and the out-position.
When the pallet is moving from the out-setup station to the out-position:
1. The out-setup station cylinder has not reached its extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the out-setup station cylinder has arrived at its extended
position, is as follows:
- The retract position sensor is on.
- The out-setup station pallet pass-through sensor (between out-position <-> out-setup station) is
detecting a pallet.
- The out-setup station pallet sensor is detecting a pallet.
- The out-position pallet sensor is not detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X07A) for the out-setup station cylinder and the
第 561 页
retract position sensor (X07B).
Check the input status of the out-setup station pallet pass-through sensor (X06F).
Check the input status of the out-setup station pallet sensor (X07F).
Check the input status of the out-position pallet sensor (X047).
------------------------------
Code: 1205408B
Display: "Pallet Transport ERROR OUT Pos. -> SETUP_ST. OUT"
Used by: CP652C
Cause: A pallet transport error occured between the out-setup station and the out-position.
When the pallet is moving from the out-position to the out-setup station:
1. The out-setup station cylinder has not reached its retract position in the 10 seconds allowed.
2. The input status for each of the sensors, after the out-setup station cylinder has arrived at its retract
position, is as follows:
- The extended position sensor is on.
- The out-setup station pallet pass-through sensor (between out-position <-> out-setup station) is not
detecting a pallet.
- The out-setup station pallet sensor is not detecting a pallet.
- The out-position pallet sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X07A) for the out-setup station cylinder and the
retract position sensor (X07B).
Check the input status of the out-setup station pallet pass-through sensor (X06F).
Check the input status of the out-setup station pallet sensor (X07F).
Check the input status of the out-position pallet sensor (X047).
------------------------------
Code: 1205408C
Display: "Pallet Transport ERROR R. Conveyor -> Filler"
Used by: CP652C
Cause: A pallet transport error occurs when the PPS filler is operating.
1. The return-conveyor out cylinder has not reached it extended position in the 10 seconds allowed.
2. The input status for each of the sensors, after the return-conveyor out cylinder has reached its
extended position, is as follows:
- The cylinder retract position sensor is on.
- The filler pallet sensor is not detecting a pallet.
- The return-conveyor pallet arrival sensor is detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the extended position sensor (X09A) for the return-conveyor out cylinder and
the retract position sensor (X09B).
Check the input status of the filler pallet sensor (X094).
Check the input status of the return-conveyor pallet arrival sensor (X09E).
------------------------------
Code: 1205408D
Display: "Pallet Transport ERROR Filler -> PPS"
Used by: CP652C
Cause: A pallet transport error occurred between the filler and the PPS6.
1. After the PPS6 has pulled the pallet in (after the cylinder on the lower conveyor has reached its
extended position), the filler pallet sensor is still detecting a pallet.
Remedy: Check that there is nothing obstructing the movement of the pallet.
Check the input status of the PPS6 lower conveyor cylinder's extended position and retract position.
Check the input status of the filler pallet sensor (X094).
------------------------------
第 562 页